CENELEC - EN IEC 61010-2-051

Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-051: Particular requirements for laboratory equipment for mixing and stirring

active, Most Current
Organization: CENELEC
Publication Date: 1 January 2021
Status: active
Page Count: 20
ICS Code (Laboratory ware and related apparatus): 71.040.20
ICS Code (Electrical and electronic testing): 19.080
scope:

Scope and object

Equipment included in scope

This part of IEC 61010 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. Such devices can contain heating elements.

NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of the IEC 61010 series as well as within the scope of this document, consideration is given to those other Part 2 standards. The standard for equipment which contains heating devices is IEC 61010-2-010.

Document History

EN IEC 61010-2-051
January 1, 2021
Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-051: Particular requirements for laboratory equipment for mixing and stirring
Scope and object Equipment included in scope This part of IEC 61010 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where...
April 1, 2015
Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-051: Particular requirements for laboratory equipment for mixing and stirring
Equipment included in scope This part of IEC 61010 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used....
October 1, 2003
Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-051: Particular requirements for laboratory equipment for mixing and stirring
A description is not available for this item.
January 1, 1995
Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use Part 2-051: Particular Requirements for Laboratory Equipment for Mechanical Mixing and Stirring
A description is not available for this item.