CSA/AM - ANSI Z21.76-2016

Gas-fired unvented catalytic room heaters for use with propane gas

active, Most Current
Organization: CSA/AM
Publication Date: 1 January 2016
Status: active
Page Count: 103
scope:

This Standard applies to newly produced unvented catalytic room heaters (see Clause 3, Definitions), hereinafter referred to as heaters, constructed entirely of new, unused parts and materials, having input ratings up to and including 40,000 Btu per hour (11 723 W) for use with propane gas, except:

a) heaters suitable for installation in bedrooms are to have input ratings of 10,000 Btu (2 931 W) per hour or less; and

b) heaters suitable for installation in bathrooms are to have input ratings of 6,000 Btu per hour (1 758 W) or less.

Unvented catalytic room heaters for installation in bedrooms or bathrooms are to be wall-mounted.

The construction of unvented catalytic room heaters for use with propane gas is covered under Clause 4.

The performance of unvented catalytic room heaters for use with propane gas is covered under Clause 5.

If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.

All references to psi throughout this Standard are to be considered gauge pressure unless otherwise specified.

Clause 2contains a list of standards specifically referenced in this Standard, and sources from which these reference standards may be obtained.

In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Document History

ANSI Z21.76-2016
January 1, 2016
Gas-fired unvented catalytic room heaters for use with propane gas
This Standard applies to newly produced unvented catalytic room heaters (see Clause 3, Definitions), hereinafter referred to as heaters, constructed entirely of new, unused parts and materials,...
January 1, 2016
Gas-fired unvented catalytic room heaters for use with propane gas
A description is not available for this item.
January 1, 1997
GAS-FIRED UNVENTED CATALTTIC ROOM HEATERS FOR USE WITH LIQUEFIED PETROLEUM (LP) GASES
A description is not available for this item.
January 1, 1996
GAS-FIRED UNVENTED CATALYTIC ROOM HEATERS FOR USE WITH LIQUEFIED PETROLEUM (LP) GASES
A description is not available for this item.
January 1, 1996
GAS-FIRED UNVENTED CATALYTIC ROOM HEATERS FOR USE WITH LIQUEFIED PETROLEUM (LP) GASES
A description is not available for this item.
January 1, 1996
Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases
PREFACE The standards set forth herein apply to the third edition of the Standard for Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases, ANSI Z21.76-1994, and...
January 1, 1996
Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases
PREFACE The standards set forth herein apply to the third edition of the Standard for Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases, ANSI Z21.76-1994, and...
January 1, 1996
Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases
PREFACE The standards set forth herein apply to the third edition of the Standard for Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases, ANSI Z21.76-1994, and...
January 1, 1994
Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases
This standard applies to newly produced unvented catalytic room heaters (see Part IV, Definitions), hereinafter referred to as heaters, constructed entirely of new, unused parts and materials, having...
January 1, 1994
Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases
This standard applies to newly produced unvented catalytic room heaters (see Part IV, Definitions), hereinafter referred to as heaters, constructed entirely of new, unused parts and materials, having...
January 1, 1994
GAS-FIRED UNVENTED CATALYTIC ROOM HEATERS FOR USE WITH LIQUEFIED PETROLEUM (LP) GASES
A description is not available for this item.
January 1, 1991
GAS-FIRED UNVENTED CATALYTIC ROOM HEATERS FOR USE WITH LIQUEFIED PETROLEUM (LP) GASES SECOND EDITION; ADDENDA Z21.76A - 1992, ADDENDA Z21.76B - 1993
PREFACE The standards set forth herein apply to the second edition of the Standard for Gas-Fired Unvented Catalytic Room Heaters For Use With Liquefied Petroleum (LP) Gases, ANSI Z21.76-1991, and...
January 1, 1988
GAS-FIRED UNVENTED CATALYTIC ROOM HEATERS FOR USE WITH LIQUEFIED PETROLEUM (LP) GASES FIRST EDITION; ADDENDA Z21.76A - 1989, ADDENDA Z21.76B - 1990
PREFACE The standards set forth herein apply to the first edition of the Standard for Gas-Fired Unvented Catalytic Room Heaters for Use With Liquefied Petroleum (LP) Gases and supersede...

References

Advertisement