ASHRAE - VC-20-A002

Superheated Condensation of Refrigerant Mixtures R448A and R452A

active, Most Current
Organization: ASHRAE
Publication Date: 1 January 2020
Status: active
Page Count: 4
scope:

INTRODUCTION

International agreements and regulations have outlined plans to phase out hydrofluorocarbon (HFC) refrigerants from a wide range of heating, ventilation, air conditioning, and refrigeration (HVAC&R) applications due to their environmental impact. Some of the proposed replacements are zeotropic mixtures of HFCs and hydrofluoroolefins (HFO). While these mixtures have the advantage of a lower GWP, their condensation differs from the condensation of pure fluids. Specifically, temperatures and compositions in the liquid and vapor phases, as well as at the liquid/vapor interface, deviate significantly from the equilibrium values during condensation. This is due to the differences in saturation temperatures of the constituent fluids at a constant pressure. Furthermore, during condensation, preferential condensation of the less volatile components leads to an accumulation of the more volatile components at the interface, depressing the local saturation temperature and introducing an additional mass transfer resistance. Pure fluid models do not account for these mass transfer related effects. There have been a limited number of investigations on condensation of HFC/HFO mixtures (Jacob et al. 2019b).

In addition, some of these zeotropic refrigerant mixtures are being proposed for applications in high temperature heat pumps and heat pump water heaters. For such applications, the refrigerant superheat temperature may be as high as 35°C (63°F)(Arpagaus et al. 2018), which leads to an increased contribution from another non-equilibrium phenomenon: superheated condensation. Conventionally, the heat transfer in condensers is modeled by assuming a local thermodynamic equilibrium and dividing the condenser in to three different regions: single-phase vapor, two-phase condensation, single-phase liquid. The local heat transfer coefficients for each region are then determined using the appropriate single or two-phase heat transfer correlations. However, past investigation (Kondou and Hrnjak 2012; Agarwal and Hrnjak 2014) on cooling of pure superheated vapors have shown that condensation begins as soon as the condenser tube wall temperature drops below the saturation temperature. This occurs upstream of the location where the refrigerant bulk enthalpy equals the saturation vapor enthalpy, which leads to development of the so-called superheated condensation region. In this region, the measured local heat transfer coefficients are much greater than those predicted by single-phase vapor correlations, due to the prevalence of latent heat transfer. As condensation occurs outside the bounds of the traditionally defined two-phase region, it is extremely important to understand the pressure drop and heat transfer for those conditions. Furthermore, accurately predicting superheated condensation heat transfer offers an opportunity to design compact heat exchangers.

Past authors have developed empirical and semi-empirical methods (Kondou and Hrnjak 2012; Agarwal and Hrnjak 2014; Xiao and Hrnjak 2017) to predict the heat transfer in the superheated condensation region for pure fluids. However, the applicability of these models to HFC/HFO refrigerant mixtures has not been addressed in the literature. Since the non-equilibrium effects during zeotropic mixture are most pronounced at relatively higher qualities, they are expected to have a significant impact on superheated condensation of these mixtures. Therefore, in this study we investigate the superheated condensation of refrigerant mixtures R448A (ΔTglide= 4.2°C/7.6°F) and R452A (ΔTglide= 2.9°C/5.2°F). Both of these mixtures are proposed replacements for R404A. We compare the measured heat transfer coefficients against predictions from past superheated condensation models, with and without corrections accounting for mixture effects. Based on the resulting agreement, we determine the applicability of these models to zeotropic HFC/HFO mixtures.

Document History

VC-20-A002
January 1, 2020
Superheated Condensation of Refrigerant Mixtures R448A and R452A
INTRODUCTION International agreements and regulations have outlined plans to phase out hydrofluorocarbon (HFC) refrigerants from a wide range of heating, ventilation, air conditioning, and...