scope:

Purpose and Scope

This Engineering Practice is a consensus document for the analysis and design of metal-clad wood-frame buildings using roof and ceiling diaphragms, alone or in combination. The roof (and ceiling) diaphragms, endwalls, intermediate shearwalls, and building frames are the main structural elements of a structural system used to efficiently resist the design lateral (wind, seismic) loads. This Engineering Practice gives acceptable methods for analyzing and designing the elements of the diaphragm system.

The provisions of this Engineering Practice are limited to the analysis of single-story buildings of rectangular shape.

Document History

December 1, 2017
Diaphragm Design of Metal-Clad, Wood-Frame Rectangular Buildings
Purpose and Scope This Engineering Practice is a consensus document for the analysis and design of metal-clad woodframe buildings using roof and ceiling diaphragms, alone or in combination. The roof...
EP484.3
December 1, 2017
Diaphragm Design of Metal-Clad, Wood-Frame Rectangular Buildings
Purpose and Scope This Engineering Practice is a consensus document for the analysis and design of metal-clad wood-frame buildings using roof and ceiling diaphragms, alone or in combination. The...
February 1, 2003
Diaphragm Design of Metal-Clad, Wood-Frame Rectangular Buildings
A description is not available for this item.
August 1, 1998
Diaphragm Design of Metal-Clad, Wood-Frame Rectangular Buildings
A description is not available for this item.
June 1, 1998
Diaphragm Design of Metal-Clad, Wood-Frame Rectangular Buildings
A description is not available for this item.
June 1, 1998
Diaphragm Design of Metal-Clad, Wood-Frame Rectangular Buildings
Purpose and Scope This Engineering Practice is a consensus document for the analysis and design of metal-clad wood-frame buildings using roof and ceiling diaphragms, alone or in combination. The...
December 1, 1997
Diaphragm Design of Metal-Clad, Post-Frame Rectangular Buildings
A description is not available for this item.
December 1, 1996
Diaphragm Design of Metal-Clad, Post-Frame Rectangular Buildings
A description is not available for this item.

References

Advertisement