IEC - 61098

Radiation protection instrumentation – Installed personnel surface contamination monitors

active, Most Current
Organization: IEC
Publication Date: 1 February 2023
Status: active
Page Count: 148
ICS Code (Radiation protection): 13.280
ICS Code (Radiation measurements): 17.240
scope:

This document applies to contamination monitors that include warning assembles and meters used for the monitoring of radioactive contamination on the surface of personnel whether they be clothed or not. The document is applicable only to that type of equipment where the user stays at the monitor. It is not applicable to the user passes quickly through the monitor. It is also not applicable to any peripheral equipment which can be associated with a particular type of equipment such as small article monitors. Probes (friskers) for measuring clothes or body by the person under monitoring or someone else are included in this document. The probes (friskers) are always connected to the monitor.

This document is applicable to the monitoring of the whole body (including the head), hands and feet, but parts of this document can be used for monitors designed for the monitoring of radioactive contamination on the hands and/or feet only. This document does not include tritium measurement.

This document is applicable to:

- installed personnel monitor (all clauses applicable);

- transportable personnel monitor (all clauses applicable);

- monitor for monitoring the hands (see the following clauses and subclauses: 2, 3, 4, 5, 6, 7.1.3, 7.2, 7.3.4, 7.4.2.2 b), 7.4.3, 7.4.4.1, 7.4.4.2, 7.4.4.3 b), 7.5, 7.6, 7.7, 8, 9, 10, 11, 12, 13 and 14);

- monitor for monitoring the feet (see the following clauses and subclauses: 2, 3, 4, 5, 6, 7.1.4, 7.2, 7.3.5, 7.4.2.2 c), 7.4.3, 7.4.4.1, 7.4.4.2, 7.4.4.3 c), 7.5, 7.6, 7.7, 8, 9, 10, 11, 12, 13 and 14); and

- monitor for monitoring the hands and feet (including probe (frisker) for whole body measurement) (see the following clauses and subclauses: 2, 3, 4, 5, 6, 7.1.3, 7.1.4, 7.1.5, 7.2, 7.3.4, 7.3.5, 7.3.6, 7.4.2.2 b), 7.4.2.2 c), 7.4.2.2 d), 7.4.3, 7.4.4.1, 7.4.4.2, 7.4.4.3 b), 7.4.4.3 c), 7.4.4.3 d),7.5, 7.6, 7.7, 8, 9, 10, 11, 12, 13 and 14).

The object of this document is to define mechanical and operational characteristics, minimum performance characteristics and general test procedures for personnel monitors.

Document History

61098
February 1, 2023
Radiation protection instrumentation – Installed personnel surface contamination monitors
This document applies to contamination monitors that include warning assembles and meters used for the monitoring of radioactive contamination on the surface of personnel whether they be clothed or...
November 1, 2003
Radiation protection instrumentation Installed personnel surface contamination monitoring assemblies
Scope and object This International Standard applies to contamination warning assemblies, meters and monitors used for the monitoring of radioactive contamination on the surface of personnel whether...
February 1, 1992
Installed Personnel Surface Contamination Monitoring Assemblies for Alpha and Beta Emitters First Edition
A description is not available for this item.