ASTM International - ASTM C958-92(2022)

Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation

active
Buy Now
Organization: ASTM International
Publication Date: 1 May 2022
Status: active
Page Count: 3
ICS Code (Raw materials): 81.060.10
scope:

1.1 This test method covers the determination of the particle size distribution of alumina or quartz powders in the range from 0.5?μm to 50 μm and having a median particle diameter from 2.5?μm to 10 μm using a sedimentation method. This test method is one of several found valuable for the measurement of particle size. Instruments used for this test method employ a constant intensity X-ray beam that is passed through a sedimenting dispersion of particles.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

abstract:

This test method details the standard procedures for the determination of the particle size distribution of alumina or quartz powders using X-ray monitoring of gravity sedimentation. This test... View More

Document History

ASTM C958-92(2022)
May 1, 2022
Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation
1.1 This test method covers the determination of the particle size distribution of alumina or quartz powders in the range from 0.5?μm to 50 μm and having a median particle diameter from 2.5?μm to 10...
January 1, 2014
Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation
1.1 This test method covers the determination of the particle size distribution of alumina or quartz powders in the range from 0.5 to 50 μm and having a median particle diameter from 2.5 to 10 μm...
May 1, 2007
Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation
1.1 This test method covers the determination of the particle size distribution of alumina or quartz powders in the range from 0.5 to 50 m and having a median particle diameter from 2.5 to 10 m using...
January 1, 2000
Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation
1.1 This test method covers the determination of the particle size distribution of alumina or quartz powders in the range from 0.5 to 50 µm and having a median particle diameter from 2.5 to 10 µm...
January 1, 2000
Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation
1.1 This test method covers the determination of the particle size distribution of alumina or quartz powders in the range from 0.5 to 50 µm and having a median particle diameter from 2.5 to 10 µm...