significance And Use:

5.1 This test method provides for the measurement of volume of pores that are in the range of catalytic importance and possibly for adsorption processes. This test method requires the use of... View More

scope:

1.1 This test method covers the determination of the total pore volume of catalysts and catalyst carriers, that is, the volume of pores having pore diameter between approximately 14 μm and 0.4 nm (4 Å).

1.2 Units-The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 Warning-Mercury has been designated by many regulatory agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA's website-http://www.epa.gov/mercury/faq.htm-for additional information. Users should be aware that selling mercury or mercury containing products, or both, into your state or country may be prohibited by law.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 8. Warning statements are given in 10.1.4, 10.1.7, and 10.1.11.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM D6761-22a
August 1, 2022
Standard Test Method for Determination of the Total Pore Volume of Catalysts and Catalyst Carriers
1.1 This test method covers the determination of the total pore volume of catalysts and catalyst carriers, that is, the volume of pores having pore diameter between approximately 14 μm and 0.4 nm (4...
April 1, 2022
Standard Test Method for Determination of the Total Pore Volume of Catalysts and Catalyst Carriers
1.1 This test method covers the determination of the total pore volume of catalysts and catalyst carriers, that is, the volume of pores having pore diameter between approximately 14 μm and 0.4 nm (4...
October 1, 2017
Standard Test Method for Determination of the Total Pore Volume of Catalysts and Catalyst Carriers
1.1 This test method covers the determination of the total pore volume of catalysts and catalyst carriers, that is, the volume of pores having pore diameter between approximately 14 µm and 0.4 nm (4...
May 1, 2012
Standard Test Method for Determination of the Total Pore Volume of Catalysts and Catalyst Carriers
1.1 This test method covers the determination of the total pore volume of catalysts and catalyst carriers, that is, the volume of pores having pore diameter between approximately 14 µm and 0.4 nm (4...
May 1, 2007
Standard Test Method for Determination of the Total Pore Volume of Catalysts and Catalyst Carriers
1.1 This test method covers the determination of the total pore volume of catalysts and catalyst carriers, that is, the volume of pores having pore diameter between approximately 14 m and 0.4 nm (4...
October 1, 2004
Standard Test Method for Determination of the Total Pore Volume of Catalysts and Catalyst Carriers
1.1 This test method covers the determination of the total pore volume of catalysts and catalyst carriers, that is, the volume of pores having pore diameter between approximately 14 m and 0.4 nm (4...
July 1, 2004
Standard Test Method for Determination of the Total Pore Volume of Catalysts and Catalyst Carriers
1.1 This test method covers the determination of the total pore volume of catalysts and catalyst carriers, that is, the volume of pores having pore diameter between approximately 14 m and 0.4 to 0.6...
February 10, 2002
Standard Test Method for Determination of the Total Pore Volume of Catalysts and Catalyst Carriers
1.1 This test method covers the determination of the total pore volume of catalysts and catalyst carriers, that is, the volume of pores having pore diameter between approximately 14 m and 0.4 to 0.6...