ASTM International - ASTM D7282-21e1

Standard Practice for Setup, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements

active
Buy Now
Organization: ASTM International
Publication Date: 15 May 2021
Status: active
Page Count: 27
ICS Code (Radiation measurements): 17.240
significance And Use:

5.1 This practice is consistent with a performance-based approach wherein the frequency of recalibration and instrument testing is linked to the results from continuing instrument quality control.... View More

scope:

1.1 This practice covers consensus criteria for the setup, calibration, and quality control of nuclear instruments. Setup establishes the operating parameters of the instrument-for example, voltage or discriminator settings. Calibrations determine the instrument's response characteristics-for example, its counting efficiency or gain. Quality control ensures that the performance of the instrument remains acceptable for its intended use and consistent with the performance at the time of calibration.

1.2 This practice addresses four of the most commonly used types of nuclear counting instruments: alpha-particle spectrometer, gamma-ray spectrometer, gas proportional counter, and liquid scintillation counter.

1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions that are provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

May 15, 2021
Standard Practice for Setup, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements
1.1 This practice covers consensus criteria for the setup, calibration, and quality control of nuclear instruments. Setup establishes the operating parameters of the instrument—for example, voltage...
ASTM D7282-21e1
May 15, 2021
Standard Practice for Setup, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements
1.1 This practice covers consensus criteria for the setup, calibration, and quality control of nuclear instruments. Setup establishes the operating parameters of the instrument—for example, voltage...
June 1, 2014
Standard Practice for Set-up, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements
5.1 This practice is consistent with a performance-based approach wherein the frequency of re-calibration and instrument testing is linked to a laboratory's continuing performance with its quality...
December 15, 2006
Standard Practice for Set-up, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements
This practice is consistent with a performance-based approach wherein the frequency of re-calibration and instrument testing is linked to a laboratory’continuing performance with its quality control...