UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

ASTM International - ASTM E1600-23

Standard Test Methods for Determination of Gold in Cyanide Solutions

active
Buy Now
Organization: ASTM International
Publication Date: 15 April 2023
Status: active
Page Count: 8
ICS Code (Other metalliferous minerals): 73.060.99
significance And Use:

4.1 In primary metallurgical processes for gold bearing ores, gold is extracted with an alkaline cyanide solution. Metallurgical accounting, process control, and ore evaluation procedures depend... View More

scope:

1.1 These test methods cover the determination of gold in ore processing cyanide solutions within the following ranges:

Method Application Range,
μg/mL
Inductively Coupled Plasma Mass Spectrometry 0.001 to 0.500
Flame Atomic Absorption Spectrometry 0.300 to 10.0

Note 1: The lower limit for the Inductively Coupled Plasma Mass Spectrometry Method, 0.001 μg/mL, was set following the guidance of Practice E1601. The reproducibility Index, R, was calculated using the total standard deviation for the lowest concentration Youden pair solution.

1.1.1 These test methods may also be applied to cyanide leach solutions from metallurgical evaluation procedures.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 The test methods appear in the following order:

Method Sections
Flame Atomic Absorption Spectrometry 9 - 16
Inductively Coupled Plasma Mass Spectrometry 17 - 24

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautions are given in 11.1.1, 11.5 and 12.2.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM E1600-23
April 15, 2023
Standard Test Methods for Determination of Gold in Cyanide Solutions
1.1 These test methods cover the determination of gold in ore processing cyanide solutions within the following ranges: Method Application Range, μg/mL Inductively Coupled Plasma Mass...
April 1, 2015
Standard Test Methods for Determination of Gold in Cyanide Solutions
1.1 These test methods cover the determination of gold in ore processing cyanide solutions within the following ranges: Method Application Range, μg/mL Inductively Coupled Plasma Mass...
April 1, 2013
Standard Test Method for Determination of Gold in Cyanide Solutions by Flame Atomic Absorption Spectrometry
1.1 This test method covers the determination of gold in ore processing cyanide solution in the range from 0.3 μg/mL to 10.0 μg/mL of gold by direct aspiration into an atomic absorption spectrometer....
June 1, 2007
Standard Test Method for Determination of Gold in Cyanide Solutions by Atomic Absorption Spectrometry
In primary metallurgical processes for gold bearing ores, gold is extracted with an alkaline cyanide solution. Metallurgical accounting, process control, and ore evaluation procedures depend on...
May 10, 2002
Standard Test Method for Determination of Gold in Cyanide Solutions by Atomic Absorption Spectrometry
1.1 This test method covers the determination of gold in ore processing cyanide solution in the range from 0.3 to 10.0 μg/mL of gold by direct aspiration into an atomic absorption...
May 10, 2002
Standard Test Method for Determination of Gold in Cyanide Solutions by Atomic Absorption Spectrometry
1.1 This test method covers the determination of gold in ore processing cyanide solution in the range from 0.3 to 10.0 μg/mL of gold by direct aspiration into an atomic absorption...
Advertisement