ASTM International - ASTM F327-08(2022)

Standard Practice for Sampling Gas Blow Down Systems and Components for Particulate Contamination by Automatic Particle Monitor Method

active
Buy Now
Organization: ASTM International
Publication Date: 1 April 2022
Status: active
Page Count: 2
ICS Code (Chemical analysis): 71.040.40
scope:

1.1 This practice describes how to connect, prepare, and sample pressurized gas systems (having up to 19.1-mm (0.75-in.) diameter lines) for particulate contamination by using an automatic monitor.

1.2 The values stated in MKS units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For hazard statements, see Section 5.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

abstract:

This practice describes the apparatuses needed, and the procedures for connecting, preparing, and sampling pressurized gas blow down systems and components for particulate contamination by the use... View More

Document History

ASTM F327-08(2022)
April 1, 2022
Standard Practice for Sampling Gas Blow Down Systems and Components for Particulate Contamination by Automatic Particle Monitor Method
1.1 This practice describes how to connect, prepare, and sample pressurized gas systems (having up to 19.1-mm (0.75-in.) diameter lines) for particulate contamination by using an automatic monitor....
May 1, 2015
Standard Practice for Sampling Gas Blow Down Systems and Components for Particulate Contamination by Automatic Particle Monitor Method
1.1 This practice describes how to connect, prepare, and sample pressurized gas systems (having up to 19.1-mm (0.75-in.) diameter lines) for particulate contamination by using an automatic monitor....
November 1, 2008
Standard Practice for Sampling Gas Blow Down Systems and Components for Particulate Contamination by Automatic Particle Monitor Method
1.1 This practice describes how to connect, prepare, and sample pressurized gas systems (having up to 19.1-mm (0.75-in.) diameter lines) for particulate contamination by using an automatic monitor....
January 1, 2000
Standard Practice for Sampling Gas Blow Down Systems and Components for Particulate Contamination by Automatic Particle Monitor Method
1.1 This practice describes how to connect, prepare, and sample pressurized gas systems (having up to 0.75-in. (19.1-mm) diameter lines) for particulate contamination by using an automatic monitor....
January 1, 2000
Standard Practice for Sampling Gas Blow Down Systems and Components for Particulate Contamination by Automatic Particle Monitor Method
1.1 This practice describes how to connect, prepare, and sample pressurized gas systems (having up to 0.75-in. (19.1-mm) diameter lines) for particulate contamination by using an automatic monitor....