DS/HD 60364-7-701/A11
Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
active
| Organization: | DS |
| Publication Date: | 3 January 2012 |
| Status: | active |
| Page Count: | 6 |
| ICS Code (Electricity supply systems): | 91.140.50 |
scope:
The particular requirements of this part of HD 60364 apply to the electrical installations in locations containing a fixed bath (bath tub) or shower and to the surrounding zones as described in this standard. This standard does not apply to emergency facilities, e.g. emergency showers used in industrial areas or laboratories.
Document History
May 28, 2018
Low-voltage electrical installations – Part 7-701: Requirements for special installations or locations – Locations containing a bath or shower
The particular requirements of this part of HD 60364 apply to the electrical installations in locations containing a fixed bath (bath tub) or shower and to the surrounding zones as described in this...
August 15, 2017
Low-voltage electrical installations – Part 7-701: Requirements for special installations or locations – Locations containing a bath or shower
The particular requirements of this part of HD 60364 apply to the electrical installations in locations containing a fixed bath (bath tub) or shower and to the surrounding zones as described in this...
July 30, 2015
Low-voltage electrical installations – Part 7-701: Requirements for special installations or locations – Locations containing a bath or shower
The particular requirements of this part of HD 60364 apply to the electrical installations in locations containing a fixed bath (bath tub) or shower and to the surrounding zones as described in this...
DS/HD 60364-7-701/A11
January 3, 2012
Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
The particular requirements of this part of HD 60364 apply to the electrical installations in locations containing a fixed bath (bath tub) or shower and to the surrounding zones as described in this...
December 16, 2011
Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
The particular requirements of this part of HD 60364 apply to the electrical installations in locations containing a fixed bath (bath tub) or shower and to the surrounding zones as described in this...
May 23, 2007
Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
The particular requirements of this part of HD 60364 apply to the electrical installations in locations containing a fixed bath (bath tub) or shower and to the surrounding zones as described in this...
Low-voltage electrical installations – Part 7-701: Requirements for special installations or locations – Locations containing a bath or shower
The particular requirements of this part of IEC 60364 apply to electrical installations in indoor or outdoor locations which contain or will contain a bath tub and/or a shower intended to be...
Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
The particular requirements of this part of HD 60364 apply to the electrical installations in locations containing a fixed bath (bath tub) or shower and to the surrounding zones as described in this...