ASTM International - ASTM D6245-25

Standard Guide on the Relationship of Indoor Carbon Dioxide Concentrations to Indoor Air Quality and Ventilation

active
Buy Now
Organization: ASTM International
Publication Date: 1 September 2025
Status: active
Page Count: 18
ICS Code (Air quality in general): 13.040.01
significance And Use:

5.1 Indoor CO2 concentrations have been used as indicators of IAQ for many years, involving both appropriate and inappropriate interpretations of indoor CO2 concentrations... View More

scope:

1.1 This guide describes the relationship of indoor carbon dioxide (CO2) concentrations to indoor air quality (IAQ) and building ventilation.

1.2 This guide contains background information on the health, comfort, and performance impacts of indoor CO2 exposure, as well as indoor CO2 limits contained in various standards and regulations.

1.3 This guide describes the estimation of CO2 generation rates from people as a function of sex, age, body mass, and level of physical activity.

1.4 This guide describes the relationship of CO2 to IAQ, including how CO2 relates to the perception of human body odor, limitations on the application of CO2 as a metric of IAQ, and the relationship of CO2 to the risk of infectious aerosol exposure.

1.5 This guide describes how CO2 concentration measurements can be used to evaluate building ventilation including mass balance analysis to determine the percent outdoor air intake at an air handler, tracer gas decay measurements to estimate whole building air change rates, and use of the constant injection tracer gas technique at equilibrium to estimate whole building air change rates.

1.6 This guide discusses concentration measurement issues, such as calibration and sensor location, and continuous indoor concentration monitoring but does not include specific test methods for either application.

1.7 This guide discusses the use of indoor CO2 concentrations for demand control ventilation (DCV) but does not contain detailed application guidance.

1.8 Units-The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM D6245-25
September 1, 2025
Standard Guide on the Relationship of Indoor Carbon Dioxide Concentrations to Indoor Air Quality and Ventilation
5.1 Indoor CO2 concentrations have been used as indicators of IAQ for many years, involving both appropriate and inappropriate interpretations of indoor CO2 concentrations (1).5 Appropriate uses...
May 1, 2024
Standard Guide on the Relationship of Indoor Carbon Dioxide Concentrations to Indoor Air Quality and Ventilation
5.1 Indoor CO2 concentrations have been used as indicators of IAQ for many years, involving both appropriate and inappropriate interpretations of indoor CO2 concentrations (1).5 Appropriate uses...
June 1, 2018
Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation
5.1 Indoor CO2 concentrations have been described and used by some people as an indicator of indoor air quality. These uses have included both appropriate and inappropriate interpretations of indoor...
April 1, 2012
Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation
Indoor CO2 concentrations have been described and used by some people as an indicator of indoor air quality. These uses have included both appropriate and inappropriate interpretations of indoor CO2...
October 1, 2007
Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation
1.1 This guide describes how measured values of indoor carbon dioxide (CO 2 ) concentrations can be used in evaluations of indoor air quality and building ventilation. 1.2 This guide describes the...
March 10, 1998
Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation
1.1 This guide describes how measured values of indoor carbon dioxide (CO2) concentrations can be used in evaluations of indoor air quality and building ventilation. 1.2 This guide describes the...
March 10, 1998
Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation
1.1 This guide describes how measured values of indoor carbon dioxide (CO2) concentrations can be used in evaluation of indoor air quality and building ventilation. 1.2 This guide describes the...