ASTM International - ASTM D8109-25

Standard Guide for Waterproofing Repair of Concrete by Chemical Grout Crack Injection

active
Buy Now
Organization: ASTM International
Publication Date: 1 December 2025
Status: active
Page Count: 7
ICS Code (Walls. Partitions. Façades): 91.060.10
ICS Code (Cement. Gypsum. Lime. Mortar): 91.100.10
significance And Use:

4.1 This guide is intended to be used in the selection and installation of chemical grout to seal leaks in concrete walls, floors, and ceilings. The procedure described in this guide focuses on... View More

scope:

1.1 This guide describes the selection of materials, installation methods, and inspection required for sealing leaks at cracks in concrete building walls and slabs using chemical grout. The process discussed in this guide is a waterproofing repair in which voids in a concrete element are sealed with a reactive solution, installed by pressurized injection through drilled or surface-mounted ports.

1.2 For interpretation of this guide as it relates to waterproofing repair by chemical grout injection into shotcrete walls, refer to Appendix X1.

1.3 This guide does not address the use of chemical grout for waterproofing by curtain grouting or injection into preplaced permeable waterstop tubes. Injection of masonry elements presents additional factors beyond the scope of this guide. This guide does not address the use of injectable materials for structural repairs or for geotechnical applications such as soil stabilization.

1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM D8109-25
December 1, 2025
Standard Guide for Waterproofing Repair of Concrete by Chemical Grout Crack Injection
4.1 This guide is intended to be used in the selection and installation of chemical grout to seal leaks in concrete walls, floors, and ceilings. The procedure described in this guide focuses on the...
January 1, 2024
Standard Guide for Waterproofing Repair of Concrete by Chemical Grout Crack Injection
4.1 This guide is intended to be used in the selection and installation of chemical grout to seal leaks in concrete walls, floors, and ceilings. The procedure described in this guide focuses on the...
December 1, 2017
Standard Guide for Waterproofing Repair of Concrete by Chemical Grout Crack Injection
4.1 This guide is intended to be used in the selection and installation of chemical grout to seal leaks in concrete walls, floors, and ceilings. The procedure described in this guide focuses on the...