UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

ASTM International - ASTM E1588-25

Standard Test Method for Primer Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Spectrometry

active
Buy Now
Organization: ASTM International
Publication Date: 15 April 2025
Status: active
Page Count: 16
ICS Code (Medical sciences and health care facilities in general): 11.020
significance And Use:

5.1 This test method is intended to be used by forensic laboratory personnel who are involved in the analysis of pGSR stubs by SEM/EDS (1, 5).

5.2 SEM/EDS analysis of pGSR is a... View More

scope:

1.1 This test method covers the analysis of primer gunshot residue (pGSR) by scanning electron microscopy/energy-dispersive X-ray spectrometry (SEM/EDS). The analysis is performed using automated software control of both the SEM and EDS systems, to screen the specimen for candidate particles that could be associated with pGSR. Manual control of the instrument is then used to perform confirmatory qualitative analysis and classification of the candidate particles.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard cannot replace knowledge, skills, or abilities acquired through education, training, and experience (Practice E2917), and is to be used in conjunction with professional judgment by individuals with such discipline-specific knowledge, skills, and abilities.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM E1588-25
April 15, 2025
Standard Test Method for Primer Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Spectrometry
1.1 This test method covers the analysis of primer gunshot residue (pGSR) by scanning electron microscopy/energy-dispersive X-ray spectrometry (SEM/EDS). The analysis is performed using automated...
September 15, 2020
Standard Practice for Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Spectrometry
1.1 This practice covers the analysis of gunshot residue (GSR) by scanning electron microscopy/energy-dispersive X-ray spectrometry (SEM/EDS). The analysis is performed using automated software...
February 1, 2017
Standard Practice for Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Spectrometry
1.1 This practice covers the analysis of gunshot residue (GSR) by scanning electron microscopy/energy-dispersive X-ray spectrometry (SEM/EDS) using manual and automated methods. The analysis may be...
May 1, 2016
Standard Practice for Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Spectrometry
1.1 This practice covers the analysis of gunshot residue (GSR) by scanning electron microscopy/energy-dispersive X-ray spectrometry (SEM/EDS) using manual and automated methods. The analysis may be...
March 1, 2016
Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Spectrometry
5.1 This document will be of use to forensic laboratory personnel who are involved in the analysis of GSR samples by SEM/EDS (4). 5.2 SEM/EDS analysis of GSR is a non-destructive method that...
June 1, 2010
Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/ Energy Dispersive X-ray Spectrometry
This document will be of use to forensic laboratory personnel who are involved in the analysis of GSR samples by SEM/EDS (4). SEM/EDS analysis of GSR is a non-destructive method that provides (5, 6)...
June 1, 2010
Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/ Energy Dispersive X-ray Spectrometry
This document will be of use to forensic laboratory personnel who are involved in the analysis of GSR samples by SEM/EDS (4). SEM/EDS analysis of GSR is a non-destructive method that provides (5, 6)...
March 15, 2008
Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/ Energy Dispersive X-ray Spectrometry
This document will be of use to forensic laboratory personnel who are involved in the analysis of GSR samples by SEM/EDS. SEM/EDS analysis of GSR is a non-destructive method that provides2 ,3 both...
February 15, 2007
Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/ Energy Dispersive X-ray Spectrometry
1.1 This guide covers the analysis of gunshot residue (GSR) by scanning electron microscopy/energy-dispersive X-ray spectrometry (SEM/EDS) by manual and automated methods. The analysis may be...
February 15, 2007
Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-ray Spectrometry
1.1 This guide covers the analysis of gunshot residue (GSR) by scanning electron microscopy/energy-dispersive X-ray spectrometry (SEM/EDS) by manual and automated methods. The analysis may be...
January 1, 2001
Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/ Energy-Dispersive Spectroscopy
1.1 This guide covers the analysis of gunshot residue (GSR) by scanning electron microscopy/energy-dispersive spectrometry (SEM/EDS) by manual and automated methods. The analysis may be performed...
January 1, 2001
Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/ Energy-Dispersive Spectroscopy
1.1 This guide covers the analysis of gunshot residue (GSR) by scanning electron microscopy/energy-dispersive spectrometry (SEM/EDS) by manual and automated methods. The analysis may be performed...
Advertisement