ASTM International - ASTM E1750-23

Standard Guide for Use of Water Triple Point Cells

active
Buy Now
Organization: ASTM International
Publication Date: 1 November 2023
Status: active
Page Count: 8
ICS Code (Temperature-measuring instruments): 17.200.20
significance And Use:

4.1 This guide describes a procedure for placing a water triple-point cell in service and for using it as a reference temperature in thermometer calibration.

4.2 The reference temperature... View More

scope:

1.1 This guide covers the nature of two commercial water triple-point cells (types A and B, see Fig. 1) and provides a method for preparing the cell to realize the water triple-point and calibrate thermometers. The qualifications concerning preparation and the types of glass used for a cell are discussed. Tests for assuring the integrity of a qualified cell and of cells yet to be qualified are given. Precautions for handling the cell to avoid breakage are also described.

FIG. 1 Configurations of two commonly used triple point of water cells, Type A and Type B, with ice mantle prepared for measurement at the ice/water equilibrium temperature. The cells are used immersed in an ice bath or water bath controlled close to 0.01?°C (see 5.5)

1.2 The effect of hydrostatic pressure on the temperature of a water triple-point cell is discussed.

1.3 Procedures for adjusting the observed SPRT resistance readings for the effects of self-heating and hydrostatic pressure are described in Appendix X1 and Appendix X2.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM E1750-23
November 1, 2023
Standard Guide for Use of Water Triple Point Cells
1.1 This guide covers the nature of two commercial water triple-point cells (types A and B, see Fig. 1) and provides a method for preparing the cell to realize the water triple-point and calibrate...
May 1, 2016
Standard Guide for Use of Water Triple Point Cells
4.1 This guide describes a procedure for placing a water triple-point cell in service and for using it as a reference temperature in thermometer calibration. 4.2 The reference temperature attained...
May 1, 2010
Standard Guide for Use of Water Triple Point Cells
This guide describes a procedure for placing a water triple-point cell in service and for using it as a reference temperature in thermometer calibration. The reference temperature attained is that...
May 1, 2009
Standard Guide for Use of Water Triple Point Cells
1.1 This guide covers the nature of two commercial water triple-point cells (types A and B, see Fig. 1) and provides a method for preparing the cell to realize the water triple-point and calibrate...
May 10, 2002
Standard Guide for Use of Water Triple Point Cells
This guide describes a procedure for placing a water triple-point cell in service and for using it as a reference temperature in thermometer calibration. The reference temperature attained is that...
January 1, 1995
Standard Guide for Use of Water Triple Point Cells
1.1 This guide covers the nature of two commercial water triple-point cells (types A and B, see Fig. 1) and provides a method for preparing the cell to realize the water triple-point and calibrate...