ASTM International - ASTM E3505-25

Standard Practice for Direct Determination of Computed Tomography (CT) Detail Detection Sensitivity and Calculation of Numerical Detection Limit

active
Buy Now
Organization: ASTM International
Publication Date: 1 July 2025
Status: active
Page Count: 9
ICS Code (Non-destructive testing): 19.100
significance And Use:

5.1 This practice provides instructions for determining the detail detection sensitivity (DDS) and its numerical limit, DDSLimit, in X-ray computed tomography (CT) volumes from disk... View More

scope:

1.1 This practice provides instructions for determining the detail detection sensitivity (DDS) and its numerical limit (DDSLimit) in slices of X-ray computed tomography (CT) volumes.

1.1.1 This practice defines image quality indicators (IQI) in the form of flat right circular cylinders (disk IQI) featuring a pattern of round or square holes of known dimension to determine the DDS.

1.1.2 This practice describes a procedure to measure the DDS with the defined disk IQI.

1.1.3 This practice describes a procedure to measure CDF, MTF, and CDD according to Test Method E1695 and Guide E1441 from the disk IQI and the estimation of the numerical limit of DDS, DDSLimit.

1.2 This practice does not intend to predict the detectability of specific object features or discontinuities in a specific application. Representative quality indicators (RQIs, Practice E1817), standard practices, and studies for probability of detection (Practices E2862 and E3023) should be considered for qualifying individual applications (see Guide E3327 and Practice E3375).

1.3 This practice describes the overall CT detail detection sensitivity (DDS) in an idealized object. Performance tests of system components such as X-ray tubes, gamma sources, and detectors are covered by separate documents (see Guide E1000, Test Method E1165, Practice E2597, Practice E2737, Test Method E2903) and should be considered for further system analysis.

1.4 This practice does not exclude other hole arrangements approved by the CEO. In such cases, the below analysis and interpretation might not be applicable, and the analysis should be described in a specific document approved by the CEO.

1.5 The values stated in SI units are to be regarded as the standard. Inch-pound units are provided for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM E3505-25
July 1, 2025
Standard Practice for Direct Determination of Computed Tomography (CT) Detail Detection Sensitivity and Calculation of Numerical Detection Limit
1.1 This practice provides instructions for determining the detail detection sensitivity (DDS) and its numerical limit (DDSLimit) in slices of X-ray computed tomography (CT) volumes. 1.1.1 This...