significance And Use:
5.1 Because of its simplicity and accuracy, the polarization resistance technique has been widely used in the laboratory in numerous metal/electrolyte systems (2, 7-10). However, its... View More
scope:
1.1 This practice covers two methods to determine the corrosion rate of steel in field and large concrete structures, that cannot be currently obtained by the current corrosion methods, Test Methods C876 and G59. The in-field measurement of the corrosion current in existing concrete structures is an essential part of the assessment of their residual safety through the calculation of the residual steel reinforcement section. Identification only of the zones that are being deteriorated as made through potential mapping (Test Method C876) is not enough because it does not give quantitative information of the loss in bar diameter needed to calculate the residual safety at structural level. The only quantitative method to measure electrochemically the rate of corrosion is the determination of the polarization resistance (Rp) (Test Method G59), which gives the corrosion current, that integrated during a period of time to calculate the accumulated corrosion, gives the corrosion depth.
1.2 The main barrier to obtaining polarization resistance in large structures (with bars longer than 1?m) is that the area of the corroding metal is unknown. The measurement on a large structure of the polarization resistance and its associated corrosion current needs the determination of the polarized area.
1.3 In this practice, the procedure for obtaining such a polarized area and the corresponding corrosion current through conducting in-field corrosion measurements on bars embedded in concrete structures using the polarization resistance method is covered. The integration of the instantaneous corrosion current over time gives the cumulative metal loss in the considered period.
1.4 Two test methods can be used to determine the polarized area and the Rp value, and from it, the instantaneous corrosion current: Test Method A using modulated current confinement by means of a guard ring and Test Method B using the attenuation of potential with the distance.
1.5 Units-The values stated in SI units are to be regarded as the standard including the corrosion current that is given in μA/cm2. No other units of measurement are included in this standard (Terminology G193).
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 9.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.