API STD 2350

Overfill Protection for Storage Tanks in Petroleum Facilities

inactive
Buy Now
Organization: API
Publication Date: 1 May 2012
Status: inactive
Page Count: 58
scope:

The scope of this standard is intended for storage tanks associated with marketing, refining, pipeline and terminals containing Class I or Class II petroleum liquids. Use is recommended for Class III petroleum liquids. This standard does not apply to:

- underground storage tanks;

- aboveground tanks of 1320 US gallons (5000 liters) or less;

- aboveground tanks which comply with PEI 600;

- pressure vessels;

- tanks containing non-petroleum liquids;

- tanks storing LPG and LNG;

- tanks at service stations;

- tanks filled exclusively from wheeled vehicles (i.e. tank trucks or railroad tank cars); and

- tanks covered by OSHA 29 CFR 1910.119 and EPA 40 CFR 68 or similar regulations.

This standard recommends application of PEI Recommended Practice 600 Recommended Practices for Overfill Prevention for Shop-Fabricated Aboveground Tanks for overfill protection where applicable for aboveground tanks falling outside the scope of this document.

Purpose

The purpose of this standard is to assist owner/operators and operating personnel in the prevention of tank overfills by implementation of a comprehensive overfill prevention process (OPP). The goal is to receive product into the intended storage tank without overfill or loss of containment.

Document History

September 1, 2020
Overfill Prevention for Storage Tanks in Petroleum Facilities
This document applies to atmospheric storage tanks associated with refining, marketing, pipeline, and terminals that contain NFPA Class I or Class II liquids. This standard does not apply to: —...
September 1, 2020
Overfill Prevention for Storage Tanks in Petroleum Facilities
This document applies to atmospheric storage tanks associated with refining, marketing, pipeline, and terminals that contain NFPA Class I or Class II liquids. This standard does not apply to: —...
API STD 2350
May 1, 2012
Overfill Protection for Storage Tanks in Petroleum Facilities
The scope of this standard is intended for storage tanks associated with marketing, refining, pipeline and terminals containing Class I or Class II petroleum liquids. Use is recommended for Class III...
January 1, 2005
Overfill Protection for Storage Tanks in Petroleum Facilities
Applicability The scope of this recommended practice (RP) is specifically limited to tanks associated with marketing, refining, pipeline and similar facilities containing Class I or Class II...
January 1, 1996
Overfill Protection for Storage Tanks in Petroleum Facilities
1.2 Scope 1.2.1 APPLICABILITY The scope of this recommended practice is specifically limited to petroleum facilities with above ground storage tanks that receive Class I liquids from mainline...
March 1, 1987
OVERFILL PROTECTION FOR PETROLEUM STORAGE TANKS FIRST EDITION
A description is not available for this item.