SNV - SN EN 20594-1

Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirements

active
Organization: SNV
Publication Date: 1 January 1995
Status: active
Page Count: 12
ICS Code (Medical sciences and health care facilities in general): 11.020
scope:

Scope and field of application

This part of IS0 594 specifies requirements for conical fittings with a 6 % (Luer) taper for use with hypodermic syringes and needles and with certain other apparatus for medical use such as transfusion and infusion sets.

It covers conical fittings made of rigid and of semi-rigid materials and includes test methods for gauging and performance. It excludes provision for more flexible or elastomeric materials.

Figure 1 illustrates typical male 6 % (Luer) conical fitting ("male fitting") and female 6 % (Luer) conical fitting ("female fitting").

NOTE - It is not practicable to define the characteristics of rigid or semi-rigid materials with precision, but glass and metal may be considered as typical rigid materials. By contrast, many plastic materials may be regarded as semi-rigid although the wall thickness is an important factor influencing the rigidity of a component.

Document History

November 1, 1997
Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirements; Amendment A1
A description is not available for this item.
September 1, 1996
Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirements; Amendment AC; Corrigendum AC
Foreword EN 1989, ISO 594-1: 1986 ‘Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment – part 1 : General requirements' was submitted to the CEN Primary...
SN EN 20594-1
January 1, 1995
Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirements
Scope and field of application This part of IS0 594 specifies requirements for conical fittings with a 6 % (Luer) taper for use with hypodermic syringes and needles and with certain other apparatus...