Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose

inactive
Organization: AAMI
Publication Date: 1 January 2013
Status: inactive
Page Count: 88
scope:

This part of ISO 11137 specifies methods for determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 25 kGy or 15 kGy as the sterilization dose to achieve a sterility assurance level, SAL, of 10-6. This part of ISO 11137 also specifies methods of sterilization dose audit used to demonstrate the continued effectiveness of the sterilization dose.

This part of ISO 11137 defines product families for sterilization dose establishment and sterilization dose audit.

Document History

January 1, 2013
Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose
This part of ISO 11137 specifies methods for determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 25 kGy or 15 kGy as the...
11137-2
January 1, 2013
Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose
This part of ISO 11137 specifies methods for determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 25 kGy or 15 kGy as the...
January 1, 2012
Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose
This part of ISO 11137 specifies methods for determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 25 kGy or 15 kGy as the...
April 10, 2009
STERILIZATION OF HEALTH CARE PRODUCTS - RADIATION - PART 2: ESTABLISHING THE STERILIZATION DOSE
A description is not available for this item.
January 1, 2006
Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose
This part of ISO 11137 specifies methods of determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 25 kGy or 15 kGy as the...