DSF/FprEN 61786-1

Measurement of DC magnetic, AC magnetic and AC electric fields from 1 Hz to 100 kHz with regard to exposure of human beings -- Part 1: Requirements for measuring instruments

pending
Organization: DS
Status: pending
Page Count: 54
ICS Code (Electromagnetic compatibility in general): 33.100.01
ICS Code (Spools. Bobbins): 55.060
scope:

This International Standard provides guidance for measuring values of quasi -static magnetic and electric fields which have a frequency content in the range 1 Hz to 100 kHz, and DC magnetic fields, to evaluate the exposure levels of the human body to these fields. Sources of fields include devices that operate at power frequencies and produce power frequency and power frequency harmonic fields, as well as devices that produce static fields, and earth magnetic static field. The magnitude ranges covered by this standard are 0,1 µT to 200 mT in AC ( 1 µT to 10 T in DC) and 1 V/m to 50 kV/m for magnetic fields and electric fields, respectively. When measurements outside this range are performed, most of the provisions of this standard will still apply, but special attention should be paid at specified uncertainty and calibration procedure. Specifically, this standard - defines terminology; - identifies requirements on field meter specifications; - indicates methods of calibration; - defines requirements on instrumentation uncertainty; - describes general characteristics of fields; - describes operational principles of instrumentation; NOTE: measurement methods that achieve defined goals pertaining to assessment of human exposure are described in IEC 61786-2 Sources of uncertainty during calibration are also identified. In regard to electric field measurements, this standard considers only the measurement of the unperturbed electric field strength at a point in free space (i.e. the electric field prior to the introduction of the field meter and operator) or above conducting surfaces.

Document History

May 27, 2014
Measurement of DC magnetic, AC magnetic and AC electric fields from 1 Hz to 100 kHz with regard to exposure of human beings - Part 1: Requirements for measuring instruments
IEC 61786-1:2013 provides guidance for measuring instruments used to measure the field strength of quasi-static magnetic and electric fields that have a frequency content in the range 1 Hz to 100 kHz...
Measurement of DC magnetic, AC magnetic and AC electric fields from 1 Hz to 100 kHz with regard to exposure of human beings – Part 1: Requirements for measuring instruments
IEC 61786-1:2013 provides guidance for measuring instruments used to measure the field strength of quasi-static magnetic and electric fields that have a frequency content in the range 1 Hz to 100 kHz...
Measurement of DC magnetic fields, AC magnetic and electric fields from 1 Hz to 100 kHz with regard to exposure of human beings - Requirements for instruments
This International Standard provides guidance for measuring values of quasi -static magnetic and electric fields which have a frequency content in the range 1 Hz to 100 kHz, and DC magnetic fields,...
DSF/FprEN 61786-1
Measurement of DC magnetic, AC magnetic and AC electric fields from 1 Hz to 100 kHz with regard to exposure of human beings -- Part 1: Requirements for measuring instruments
This International Standard provides guidance for measuring values of quasi -static magnetic and electric fields which have a frequency content in the range 1 Hz to 100 kHz, and DC magnetic fields,...