UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

GPA - STD 2177

Analysis of Natural Gas Liquid Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography

inactive
Organization: GPA
Publication Date: 1 January 2013
Status: inactive
Page Count: 18
scope:

This method is intended for the analysis of demethanized liquid hydrocarbon streams containing nitrogen/air and carbon dioxide, and purity products such as an ethane/propane mix that fall within the compositional ranges listed in Table I. This method is limited to mixtures containing less than 5 mole percent of heptanes and heavier fractions (20 mole percent of hexanes and heavier fractions).

The heptanes and heavier fraction if present in the sample is analyzed by either (1) use of a pre-cut column to elute heptanes and heavier first as a single peak, or (2) reverse flow of carrier gas after n-hexane, and peak grouping of the heptanes plus fraction. For purity mixes without heptanes and heavier, no reverse of carrier flow is required.

NOTE 1 - This method can be used for a hexanes plus analysis by adjusting the timing of the backflush event to occur following the elution of n-pentane.

NOTE 2 - CAUTION: In the case of unknown samples with a relatively large C6 + or C7 + fraction and where precise results are important, it is desirable to determine the molecular weight (or other pertinent physical properties) of these fractions. Since this method makes no provision for determining physical Properties, the physical properties needed must be determined by extended analysis or agreed to by the contracting parties. The extended analysis will be made according to GPA Publication 2186.

NOTE 3 - For samples containing more than 5 mole percent of heptanes and heavier fractions (20 mole percent of hexanes and heavier fractions), analysis will be made according to GPA Publication 2103.

Document History

January 1, 2020
Analysis of Natural Gas Liquids by Gas Chromatography
This method is intended for the analysis of NGL mixtures which may contain nitrogen/air and carbon dioxide, as well as purity products that fall within the compositional ranges listed in Table 1....
STD 2177
January 1, 2013
Analysis of Natural Gas Liquid Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography
This method is intended for the analysis of demethanized liquid hydrocarbon streams containing nitrogen/air and carbon dioxide, and purity products such as an ethane/propane mix that fall within the...
January 1, 2003
Analysis of Natural Gas Liquid Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography
This method is intended for the analysis of demethanized liquid hydrocarbon streams containing nitrogen/air and carbon dioxide, and purity products such as an ethane/propane mix that fall within the...
January 1, 1995
Analysis of Demethanized Hydrocarbon Liquid Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography; Errata - 1995
A description is not available for this item.

References

Advertisement