CSA - CAN/CSA-C22.2 NO. 60601-1-10-09
Medical electrical equipment - Part 1-10: General requirements for basic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loop controllers
inactive
| Organization: | CSA |
| Publication Date: | 1 January 2009 |
| Status: | inactive |
| Page Count: | 104 |
| ICS Code (Medical equipment): | 11.040 |
Document History
January 1, 2021
Medical electrical equipment — Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers
This Standard applies to ME EQUIPMENT and ME SYSTEMS that are intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I.
January 1, 2014
Medical electrical equipment — Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers
– "the general standard" designates IEC 60601-1 alone (IEC 60601-1:2005+A1:2012);
– "this collateral standard" designates IEC 60601-1-10 alone (IEC 60601-1- 10:2007+A1:2013)
January 1, 2014
Amendment 1 Medical electrical equipment - Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers
- "the general standard" designates IEC 60601-1 alone (IEC 60601-1:2005+A1:2012);
– "this collateral standard" designates IEC 60601-1-10 alone (IEC 60601-1- 10:2007+A1:2013)
November 1, 2009
Medical electrical equipment — Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS....
CAN/CSA-C22.2 NO. 60601-1-10-09
January 1, 2009
Medical electrical equipment - Part 1-10: General requirements for basic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loop controllers
A description is not available for this item.
January 1, 2009
Medical electrical equipment — Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS....