scope:

This standard applies to automatically operating gas-fired central furnaces (see Part XI, Definitions), hereinafter referred to as furnaces, for installation in residential, commercial, and industrial structures including furnaces for Direct Vent, Recreational Vehicle, Outdoor, and Manufactured (Mobile) Homes. These furnaces may include a cooling unit. All units shall be constructed entirely of new, unused parts and materials.

In Canada, this standard applies to gas-fired central furnaces having inputs up to and including 400,000 Btu per hour (ll7 228 W).

This standard applies to Category I, Category II, Category III and Category IV Central Furnaces (see Part XI, Definitions).

This standard applies to furnaces of the types defined in Part XI, Definitions, which are designed to supply heated air through ducts to spaces remote from or adjacent to the furnace location. Location and use of such furnaces with respect to the spaces being heated necessitates automatic operation of the appliance.

This standard covers the thermal efficiency (2.38) and related markings of only those furnaces whose efficiencies are not regulated in the U.S.A. by the Energy Policy Act and Conservation Act of 1975 and the National Energy Conservation Policy of 1978* or not covered in Canada by Exhibit M (M1.1), when connected to single phase electrical supply.

A furnace of a type not specifically defined in this standard may be subjected to such examination and tests as deemed necessary by the testing agency to determine compliance with the intent of this standard.

This standard also applies to a furnace which is factory equipped with both a draft hood and an automatic vent damper device (see Part XI, Definitions), hereinafter referred to as vent damper device.

Unless otherwise indicated on its rating plate, a furnace shall be for installation indoors in accordance with its markings and the manufacturer's installation instructions. When specified additional or alternate provisions are met, a furnace may be for manufactured (mobile) home installation or for use outdoors.

A furnace for manufactured (mobile) home installation shall be designed so when installed in accordance with the manufacturer's installation instructions supplied with the furnace, it shall provide complete separation of its combustion system from the living space of the manufactured (mobile) home. The complete separation of the furnace combustion system from the living space of the manufactured (mobile) home is accomplished by the furnace being designed and installed so (1) all air supplied for combustion, (2) the combustion system of the furnace and (3) all products of combustion are completely isolated from the living space. Doors, panels and any other access openings of the structure serving an enclosure required for such isolation are to communicate only to the outdoors. A furnace which by its inherent design provides such complete separation is referred to as a direct vent central furnace (see Part XI, Definitions).

A furnace shall be for use with one or more of the gases specified in 2.1.1 A furnace for manufactured (mobile) home installation shall be convertible for use with natural gas and liquefied petroleum gases.

Special construction provisions applicable to Category II, III, or Iv furnaces are outlined under 1.1.10, 1.2.23, 1.2.24, 1.14, 1.15.15 through 1.15.17, 1.23.1, -c13, -c16, -d4, and -d5, 1.24.2-i and -j, 1.25.2-d and 1.25.9-f.

A furnace for indoor installation designed to vent the flue gases horizontally through an outside wall shall be specified as Category III or IV, except Category I furnaces utilizing a listed mechanical venter applied externally to the venting system.

Special construction provisions applicable to a furnace for manufactured (mobile) home installation are outlined under 1.1.8, 1.1.9, 1.1.10, 1.2.22, 1.6.5, 1.11.17, 1.23.1-c4, 1.23.5, 1.25.2-f, 1.25.9-b and 1.25.9-h and Part III. 1.1.14 Special construction provisions

Document History

January 1, 2021
Gas-fired central furnaces
This Standard applies to automatically operating gas-fired central furnaces (see Clause 3), hereinafter referred to as furnaces, for installation in residential, commercial, and industrial structures...
January 1, 2016
Gas-fired central furnaces
This Standard applies to automatically operating gas-fired central furnaces (see Clause 3, Definitions), hereinafter referred to as furnaces, for installation in residential, commercial, and...
June 1, 2012
Standard for Gas-fired central furnaces
This standard applies to automatically operating gas-fired central furnaces (see Part X, Definitions), hereinafter referred to as furnaces, for installation in residential, commercial, and industrial...
June 1, 2008
Gas-Fired Central Furnaces
A description is not available for this item.
June 1, 2008
Gas-Fired Central Furnaces
A description is not available for this item.
October 1, 2007
Gas-Fired Central Furnaces
Preface The standards set forth herein apply to the fifth edition of the Standard for Gas-Fired Central Furnaces, Z21.47-2006 CSA 2.3-2006 and supersede corresponding standards therein. Following...
October 1, 2007
Gas-Fired Central Furnaces
Preface The standards set forth herein apply to the fifth edition of the Standard for Gas-Fired Central Furnaces, Z21.47-2006 • CSA 2.3-2006 and supersede corresponding standards therein. Following...
January 1, 2006
Gas-Fired Central Furnaces
This standard applies to automatically operating gas-fired central furnaces see Part XI, Definitions, hereinafter referred to as furnaces, for installation in residential, commercial, and industrial...
January 1, 2006
Gas-Fired Central Furnaces
This standard applies to automatically operating gas-fired central furnaces see Part XI, Definitions, hereinafter referred to as furnaces, for installation in residential, commercial, and industrial...
Gas-Fired Central Furnaces
Preface This publication represents a basic standard for safe operation, substantial and durable construction, and acceptable performance of gas-fired central furnaces. It is the result of years of...
November 1, 2003
Gas-Fired Central Furnaces
PREFACE The standards set forth herein apply to the fourth edition of the Standard for Gas-Fired Central Furnaces, ANSI Z21.47-2003 CSA 2.3-2003, ANSI Z21.47a-2004 CSA 2.3a-2004 and supersede...
Gas-Fired Central Furnaces
This standard applies to automatically operating gas-fired central furnaces (see Part XI, Definitions), hereinafter referred to as furnaces, for installation in residential, commercial, and...
November 1, 2001
Gas-Fired Central Furnaces
This standard applies to automatically operating gas-fired central furnaces (see Part XI, Definitions), hereinafter referred to as furnaces, for installation in residential, commercial, and...
November 1, 2001
Gas-Fired Central Furnaces
PREFACE This publication represents a basic standard for safe operation, substantial and durable construction, and acceptable performance of gas-fired central furnaces. It is the result of years of...
Gas-Fired Central Furnaces
This standard applies to automatically operating gas-fired central furnaces (see Part XI, Definitions), hereinafter referred to as furnaces, for installation in residential, commercial, and...
January 1, 2000
Gas-Fired Central Furnaces
PREFACE The standards set forth herein apply to the second edition of the Standard for Gas-Fired central furnaces, ANSI Z21.47-1998 * CSA 2.3-M98, and addenda ANSI Z21.47A-1999 * CSA 2.3A-M99, and...
January 1, 1999
Gas-Fired Central Furnaces
PREFACE The standards set forth herein apply to the first edition of the Standard for Gas-Fired Central Furnaces, ANSI 221.47-1 998 - CSA 2.3-MQ8, and supersede corresponding standards therein....
January 1, 1998
Gas-Fired Central Furnaces
PREFACE This publication represents a basic standard for safe operation, suibstantial and durable construction, and acceptable performance of gasfired central furnaces. It is the result of years of...
January 1, 1995
Gas-Fired Central Furnaces
PREFACE The standards set forth herein apply to the first edition of the Standard for Gas-Fired Central Furnaces, ANSI Z21.47-1993 - CAN/CGA-23-M93, and supersede corresponding standards themin....
ANSI Z21.47/CSA 2.3
January 1, 1993
Gas-Fired Central Furnaces
This standard applies to automatically operating gas-fired central furnaces (see Part XI, Definitions), hereinafter referred to as furnaces, for installation in residential, commercial, and...
January 1, 1990
GAS-FIRED CENTRAL FURNACES (EXCEPT DIRECT VENT CENTRAL FURNACES) TWENTY-FOURTH EDITION; ADDENDA Z21.47A - 1990, ADDENDA Z21.47B - 1992
This publication represents a standard for safe operation, substantial and durable construction, and acceptable performance of gas-fired central furnaces of other than the direct vent type. It is the...
January 1, 1987
GAS-FIRED CENTRAL FURNACES (EXCEPT DIRECT VENT CENTRAL FURNACES) TWENTY-THIRD EDITION; ADDENDA Z21.47A - 1988, ADDENDA Z21.47B - 1989
PREFACE The standards set forth herein apply to the twenty-third edition of the Standard for Gas-Fired Central Furnaces (Except Direct Vent Central Furnaces), ANSI Z21.47-1987, and Addenda thereto,...
January 1, 1983
GAS-FIRED CENTRAL FURNACES (EXCEPT DIRECT VENT AND SEPARATED COMBUSTION SYSTEM CENTRAL FURNACES); ADDENDA Z21.47A - 1985, ADDENDA Z21.47B - 1986
PREFACE The standards set forth herein apply to the twenty-second edition of the Standard for Gas-Fired Central Furnaces (Except Direct Vent Central Furnaces) , ANSI Z21.47-1983, and Addenda...