API MPMS 21.2
Manual of Petroleum Measurement Standards Chapter 21 - Flow Measurement Using Electronic Metering Systems Section 2 - Flow Measurement using Electronic Metering Systems, Inferred Mass
| Organization: | API |
| Publication Date: | 1 August 2000 |
| Status: | inactive |
| Page Count: | 19 |
scope:
This Addendum specifically covers inferred mass measurement
systems utilizing flow computers as the tertiary flow calculation
device and either turbine or displacement type meters, working with
on-line density meters, as the primary measurement devices. The
Scope does not include system using calculated flowing densities,
i.e., Equations of State. The hardware is essentially identical to
that referenced in API MPMS Chapter 21.2 and the methods
and procedures are as described in API MPMS Chapters 14.4,
14.6, 14.7 and 14.8. Audit, record keeping, collection and
calculation interval
APPLICATION
The procedures and techniques discussed in this document are recommended for use with new measurement applications. Liquid measurement using existing equipment and techniques not in compliance with this standard may have a higher uncertainty than liquid measurement based on the recommendations contained in this document.
ELECTRONIC LIQUID MEASUREMENT (ELM)
The term "electronic liquid measurement," or ELM, will be freely used throughout this document to denote liquid measurement using electronic metering systems. (Also see 3.20 in Chapter 21.2.)
Document History