NPFC - MIL-M-24144

MONITORS, FROST-POINT/DEW-POINT, COMPRESSED AIR, SEMI-PORTABLE

active, Most Current
Buy Now
Organization: NPFC
Publication Date: 25 April 1988
Status: active
Page Count: 32
scope:

This specification covers semi-portable frost/dew point monitors used to determine the moisture content of shipboard compressed air systems.

Monitors shall be of the following types and pressure ranges as specified.

Monitor types shall be as follows:

Chilled surface monitor (CSM) - dew point temperature determined by visual or automatic detection of vapor condensation on a chilled mirror surface exposed to sample air (see 6.2).

Direct reading hygrometer (DRH) - dew point temperature determined by measuring the electrical properties of a sensing device exposed to sample air (see 6.2). Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Sea Systems Command, SEA 55Z3, Department of the Navy, Washington, DC 20362-5101 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter.

Pressure ranges for either type shall be as follows:

Low pressure (LP)- 1 to 150 pounds per square inch (lb/in2).

High pressure (HP)- 3,000 to 5,000 lb/in2 (see 6.2).

intended Use:

Monitors are intended to support maintenance of Navy shipboard compressed air dehydrators.

Document History

MONITORS, FROST-POINT/DEW-POINT, COMPRESSED AIR, SEMI-PORTABLE
A description is not available for this item.
MIL-M-24144
April 25, 1988
MONITORS, FROST-POINT/DEW-POINT, COMPRESSED AIR, SEMI-PORTABLE
This specification covers semi-portable frost/dew point monitors used to determine the moisture content of shipboard compressed air systems. Monitors shall be of the following types and pressure...
June 30, 1978
MONITORS, FROST-POINT/DEW-POINT, COMPRESSED AIR, SEMI-PORTABLE
A description is not available for this item.
July 1, 1968
MONITORS, FROST-POINT/DEW-POINT, COMPRESSED AIR, SEMI-PORTABLE
A description is not available for this item.
March 2, 1967
MONITORS, FROST-POINT/DEW-POINT, COMPRESSED AIR, SEMI-PORTABLE
A description is not available for this item.