ASTM International - ASTM D5996-96(2000)

Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography

inactive
Buy Now
Organization: ASTM International
Publication Date: 1 January 2000
Status: inactive
Page Count: 5
ICS Code (Physicochemical methods of analysis): 71.040.50
scope:

1.1 This test method covers on-line analysis of high-purity water by the ion chromatography technique. This test method is applicable for measuring various anionic contaminants in high-purity water, typically in the range of 0.02 to 100 µg/L. This test method is used to determine the concentration of acetate, formate, chloride, fluoride, phosphate, nitrate, and sulfate in a continuously flowing sample. The range of the test method is only as good as the reagent water available for preparing standards. At extremely low concentrations, <1.0 µg/L, preparing standards is difficult, and extra care must be taken in their preparation. The sample may have to be conditioned from higher pressures and temperatures to conditions that are suitable for use by on-line instruments. The range of the test method is only as good as the reagent water available for standard preparation.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document History

February 15, 2016
Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography
5.1 In the power-generation industry, high-purity water is used to reduce corrosion from anions, such as sulfate, chloride, and fluoride. These anions are known to be detrimental to materials of...
October 1, 2009
Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography
In the power-generation industry, high-purity water is used to reduce corrosion from anions, such as sulfate, chloride, and fluoride. These anions are known to be detrimental to materials of...
June 1, 2005
Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography
1.1 This test method covers on-line analysis of high-purity water by the ion chromatography technique. This test method is applicable for measuring various anionic contaminants in high-purity water,...
ASTM D5996-96(2000)
January 1, 2000
Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography
1.1 This test method covers on-line analysis of high-purity water by the ion chromatography technique. This test method is applicable for measuring various anionic contaminants in high-purity water,...
Advertisement