UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

ASTM International - ASTM E2260-03

Standard Guide for Repointing (Tuckpointing) Historic Masonry

inactive
Buy Now
Organization: ASTM International
Publication Date: 10 February 2003
Status: inactive
Page Count: 4
ICS Code (Masonry): 91.080.30
significance And Use:

Repointing masonry improves weather resistance, reduces water penetration, maintains structural and visual integrity, and prolongs the life of the building by allowing a mortar joint to shed water... View More

scope:

1.1 This guide applies only to existing historic masonry construction. For purposes of this guide historic masonry is intended to refer to buildings that have significant historic, architectural, cultural or social meaning and are constructed of masonry materials. Similar techniques and evaluation should be employed for non-historic masonry, but are not addressed in this guide.

1.2 This guide outlines procedures for repointing historic masonry and is intended to provide guidelines for the user to establish project-specific requirements for repointing of historic masonry.

1.3 This guide only pertains to masonry units: brick, terra cotta, stone, cast stone, and concrete brick laid in mortar, and may or may not be appropriate for other masonry units.

1.4 This guide addresses repointing (tuckpointing) as defined in .

1.5 When considering repointing, especially on masonry of artistic, architectural, cultural, or historical significance, guidance from a specialist experienced in historic masonry and repointing should be sought.

1.6 This guide does not address pointing styles or profiles used on masonry or the methods of producing them.

1.7 Additional repairs that may impact the structural integrity of the masonry may necessitate that a structural stability analysis be completed prior to the execution of any work.

1.8 Following this guide may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Document History

October 15, 2021
Standard Guide for Repointing (Tuckpointing) Historic Masonry
1.1 This guide applies only to existing historic masonry construction. For purposes of this guide historic masonry is intended to refer to buildings that have significant historic, architectural,...
April 15, 2021
Standard Guide for Repointing (Tuckpointing) Historic Masonry
1.1 This guide applies only to existing historic masonry construction. For purposes of this guide historic masonry is intended to refer to buildings that have significant historic, architectural,...
January 1, 2012
Standard Guide for Repointing (Tuckpointing) Historic Masonry
1.1 This guide applies only to existing historic masonry construction. For purposes of this guide historic masonry is intended to refer to buildings that have significant historic, architectural,...
January 1, 2012
Standard Guide for Repointing (Tuckpointing) Historic Masonry
1.1 This guide applies only to existing historic masonry construction. For purposes of this guide historic masonry is intended to refer to buildings that have significant historic, architectural,...
ASTM E2260-03
February 10, 2003
Standard Guide for Repointing (Tuckpointing) Historic Masonry
1.1 This guide applies only to existing historic masonry construction. For purposes of this guide historic masonry is intended to refer to buildings that have significant historic, architectural,...
Advertisement