ASTM International - ASTM F431-03

Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners

inactive
Buy Now
Organization: ASTM International
Publication Date: 1 October 2003
Status: inactive
Page Count: 12
scope:

1.1 This specification covers the acceptable details and tolerances for the plenum chamber used in specified air performance measurement tests for vacuum cleaners.

1.2 The plenum chamber is designed for vacuum measurements only. (Warning-The plenum chamber has been shown to accurately determine maximum air power values at various test points for vacuum cleaners. There is a possibility that the airflow values measured with orifices larger than 2 in. at high flow rates may be erroneous due to the proximity of the top and bottom surfaces to the orifice plate inlet.)

1.3 The foot-pound, inch system of units is used in this standard. The values in parentheses are given for information only.

Document History

February 1, 2021
Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners
1.1 This specification covers the acceptable details and tolerances for the plenum chamber used in specified air performance measurement tests for vacuum cleaners. 1.2 The plenum chamber is designed...
May 1, 2013
Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners
1.1 This specification covers the acceptable details and tolerances for the plenum chamber used in specified air performance measurement tests for vacuum cleaners. 1.2 The plenum chamber is designed...
November 1, 2008
Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners
1.1 This specification covers the acceptable details and tolerances for the plenum chamber used in specified air performance measurement tests for vacuum cleaners. 1.2 The plenum chamber is designed...
August 1, 2004
Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners
1.1 This specification covers the acceptable details and tolerances for the plenum chamber used in specified air performance measurement tests for vacuum cleaners. 1.2 The plenum chamber is designed...
ASTM F431-03
October 1, 2003
Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners
1.1 This specification covers the acceptable details and tolerances for the plenum chamber used in specified air performance measurement tests for vacuum cleaners. 1.2 The plenum chamber is designed...
October 10, 1998
Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners
1.1 This specification covers the acceptable details and tolerances for the plenum chamber used in specified air performance measurement tests for vacuum cleaners. 1.2 The plenum chamber is designed...