UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

ASTM International - ASTM D5011-92(1997)e1

Standard Practices for Calibration of Ozone Monitors Using Transfer Standards

inactive
Buy Now
Organization: ASTM International
Publication Date: 10 September 1997
Status: inactive
Page Count: 27
scope:

1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards.

1.2 These practices describe five types of transfer standards: (A) Analytical instruments (B) Boric acid potassium iodide (BAKI) manual analytical procedure (C) Gas phase titration with excess nitric oxide (D) Gas phase titration with excess ozone (E) Ozone generator device.

1.3 These practices describe procedures to establish the authority of transfer standards: qualification, certification, and periodic recertification.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 8 for specific precautionary statements.

Document History

October 1, 2017
Standard Practices for Calibration of Ozone Monitors Using Transfer Standards
1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards. 1.2 These practices describe five types of transfer standards: Practice...
March 1, 2009
Standard Practices for Calibration of Ozone Monitors Using Transfer Standards
The reactivity and instability of O3 precludes the storage of O3 concentration standards for any practical length of time, and precludes direct certification of O3 concentrations as SRM's. Moreover,...
April 10, 2003
Standard Practices for Calibration of Ozone Monitors Using Transfer Standards
1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards. 1.2 These practices describe five types of transfer standards: (A)...
ASTM D5011-92(1997)e1
September 10, 1997
Standard Practices for Calibration of Ozone Monitors Using Transfer Standards
1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards. 1.2 These practices describe five types of transfer standards: (A)...
Advertisement