UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

ASTM International - ASTM D5543-09

Standard Test Methods for Low-Level Dissolved Oxygen in Water

inactive
Buy Now
Organization: ASTM International
Publication Date: 1 October 2009
Status: inactive
Page Count: 5
ICS Code (Examination of water for chemical substances): 13.060.50
significance And Use:

Dissolved oxygen is detrimental in certain boiler and steam cycles because it may accelerate corrosion. Concentrations above 10 μg/L are unacceptable in many high-pressure boiler systems. The... View More

scope:

1.1 This test method covers the determination of low-level (<100μ g/L) dissolved oxygen in thermal-cycle steam condensate, deaerated boiler feedwater, boiler water, and deaerated deionized water. The following test method is included:

Range, μg/LSections
Color Comparator Test
Method Using Self-Filling Glass
Ampoules
0 to 100 8 to 17

1.2 This test method may be applicable to electronic-grade, pharmaceutical-grade, and other high-purity waters, although these were not addressed in the collaborative study.

1.3 This test method is a colorimetric procedure applicable to dissolved oxygen in water in the range from 0 to 100 μg/L.

1.4 It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.

1.5 The values stated in SI units are to be regarded as the standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

8.1 This test method covers the rapid, routine determination of dissolved oxygen in steam condensate, deaerated boiler feedwater, and deaerated deionized water. Color comparators allow the estimation of concentrations ranging from 0 to 100 μg/L (ppb) oxygen.

8.2 This test method was tested in steam condensate, deaerated boiler feedwater, and deaerated deionized water. It is the user's responsibility to ensure the validity of the test method for waters of untested matrices.

Document History

July 1, 2021
Standard Test Method for Low-Level Dissolved Oxygen in Water
1.1 This test method covers the rapid determination of low-level (<100 µg/L) dissolved oxygen in thermal-cycle steam condensate, deaerated boiler feedwater, boiler water, and deaerated deionized...
February 1, 2015
Standard Test Method for Low-Level Dissolved Oxygen in Water
1.1 This test method covers the rapid determination of low-level (<100 μg/L) dissolved oxygen in thermal-cycle steam condensate, deaerated boiler feedwater, boiler water, and deaerated deionized...
ASTM D5543-09
October 1, 2009
Standard Test Methods for Low-Level Dissolved Oxygen in Water
1.1 This test method covers the determination of low-level (<100μ g/L) dissolved oxygen in thermal-cycle steam condensate, deaerated boiler feedwater, boiler water, and deaerated deionized water. The...
January 1, 2005
Standard Test Methods for Low-Level Dissolved Oxygen in Water
1.1 These test methods cover the determination of low-level (∧lt;100 [mu]g/L) dissolved oxygen in thermal-cycle steam condensate, deaerated boiler feedwater, boiler water, and deaerated deionized...
June 10, 1999
Standard Test Methods for Low-Level Dissolved Oxygen in Water
1.1 These test methods cover the determination of low-level (∧lt;100 [mu]g/L) dissolved oxygen in thermal-cycle steam condensate, deaerated boiler feedwater, boiler water, and deaerated deionized...
Advertisement