UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

ASTM International - ASTM F2502-05(2009)e1

Standard Specification and Test Methods for Bioabsorbable Plates and Screws for Internal Fixation Implants

inactive
Buy Now
Organization: ASTM International
Publication Date: 1 August 2009
Status: inactive
Page Count: 11
ICS Code (Implants for surgery, prosthetics and orthotics): 11.040.40
significance And Use:

Biodegradable devices are expected by intention to deteriorate over time once they are implanted into the body. This makes a removal operation unnecessary, which is especially advantageous... View More

scope:

1.1 This specification and test methods covers a mechanical characterization reference for hydrolytically degradable polymer resin (from this point on referenced as "bioabsorbable") plates and screws for orthopedic internal fixation.

1.2 This specification establishes a common terminology to describe the size and other physical characteristics of bioabsorbable implants and performance definitions related to the performance of bioabsorbable devices.

1.3 This specification establishes standard test methods to consistently measure performance-related mechanical characteristics of bioabsorbable devices when tested under defined conditions of pretreatment, temperature, humidity, and testing machine speed.

1.4 This specification may not be appropriate for all bioabsorbable devices. The user is cautioned to consider the appropriateness of the standard in view of the particular bioabsorbable device and its potential application.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document History

September 1, 2017
Standard Specification and Test Methods for Absorbable Plates and Screws for Internal Fixation Implants
1.1 This specification and test methods cover the mechanical characterization of plates and screws for orthopedic internal fixation. Covered devices are fabricated from one or more hydrolytically...
June 1, 2011
Standard Specification and Test Methods for Absorbable Plates and Screws for Internal Fixation Implants
1.1 This specification and test methods cover the mechanical characterization of plates and screws for orthopedic internal fixation. Covered devices are fabricated from one or more hydrolytically...
ASTM F2502-05(2009)e1
August 1, 2009
Standard Specification and Test Methods for Bioabsorbable Plates and Screws for Internal Fixation Implants
1.1 This specification and test methods covers a mechanical characterization reference for hydrolytically degradable polymer resin (from this point on referenced as “bioabsorbable”) plates and screws...
October 1, 2005
Standard Specification and Test Methods for Bioabsorbable Plates and Screws for Internal Fixation Implants
1.1 This specification and test methods covers a mechanical characterization reference for hydrolytically degradable polymer resin (from this point on referenced as "bioabsorbable") plates and screws...