ASTM International - ASTM D2898-10

Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing

inactive
Buy Now
Organization: ASTM International
Publication Date: 1 March 2010
Status: inactive
Page Count: 4
ICS Code (Wood-protecting chemicals): 71.100.50
significance And Use:

This practice describes different methods of exposing fire-retardant-treated wood products or assemblies to controlled accelerated weathering or conditioning.

The conditioning... View More

scope:

1.1 This practice addresses the durability of a fire-retardant treatment of wood products by exposure to accelerated cycles of wetting, drying, or ultraviolet (UV) exposure, or combination thereof, prior to evaluation by a fire response test. Four conditioning methods are described.

1.2 This practice is applicable to wood products that have been treated with fire-retardant chemicals by pressure impregnation.

1.3 The test specimens are to be in the form of, or suitable for fabrication into, test specimens, such as those described in Test Methods E84, E108, and E1354 and other standard test methods for evaluating the fire performance of fire-retardant-treated wood products.

1.4 The text of these methods references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of these test methods.

1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document History

February 1, 2017
Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
1.1 This practice addresses the durability of a fire-retardant treatment of wood products by exposure to accelerated cycles of wetting, drying, or ultraviolet (UV) exposure, or combination thereof,...
ASTM D2898-10
March 1, 2010
Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
1.1 This practice addresses the durability of a fire-retardant treatment of wood products by exposure to accelerated cycles of wetting, drying, or ultraviolet (UV) exposure, or combination thereof,...
September 15, 2009
Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
1.1 This practice addresses the durability of a fire-retardant treatment of wood products by exposure to accelerated cycles of wetting, drying, or ultraviolet (UV) exposure, or combination thereof,...
November 1, 2008
Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
1.1 This practice covers the durability of a fire-retardant treatment of wood under exposure to accelerated weathering. Four conditioning methods are described. Methods are suitable for application...
November 1, 2008
Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
1.1 This practice covers the durability of a fire-retardant treatment of wood under exposure to accelerated weathering. Four conditioning methods are described. Methods are suitable for application...
April 15, 2007
Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
1.1 This practice covers the durability of a fire-retardant treatment of wood under exposure to accelerated weathering. Two conditioning methods are described, both suitable for application to a test...
October 1, 2004
Standard Test Methods for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
1.1 These test methods cover the durability of a fire-retardant treatment of wood under exposure to accelerated weathering. It is intended that fire-retardant treatment of the specimen be by pressure...
April 10, 1999
Standard Test Methods for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
1.1 These test methods cover the durability of a fire-retardant treatment of wood under exposure to accelerated weathering. It is intended that fire-retardant treatment of the specimen be by pressure...
January 1, 1977
Standard Methods for Accelerated Weathering Of Fire-Retardant-Treated Wood For Fire Testing
A description is not available for this item.
Advertisement