ASTM International - ASTM D6581-12
Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography
| Organization: | ASTM International |
| Publication Date: | 1 March 2012 |
| Status: | inactive |
| Page Count: | 23 |
| ICS Code (Examination of water for chemical substances): | 13.060.50 |
significance And Use:
4.1 The oxyhalides chlorite, chlorate, and bromate are inorganic disinfection by-products (DBPs) of considerable health risk concern worldwide. The occurrence of chlorite and chlorate is... View More
scope:
1.1 These multi-test methods cover the determination of the oxyhalides-chlorite,
| Range | Sections | |
| Test Method A: Chemically Suppressed Ion Chromatography | 8 to 20 | |
| Chlorite | 5 to 500 µg/L | |
| Bromate | 1 to 25 µg/L | |
| Bromide | 5 to 250 µg/L | |
| Chlorate | 5 to 500 µg/L | |
| Test Method B: Electrolytically Suppressed Ion Chromatography | 21 to 31 | |
| Chlorite | 20 to 1000 µg/L | |
| Bromate | 1 to 30 µg/L | |
| Bromide | 20 to 200 µg/L | |
| Chlorate | 20 to 1000 µg/L |
1.1.1 The upper limits may be extended by appropriate sample dilution or by the use of a smaller injection volume. Other ions of interest, such as fluoride, chloride, nitrite, nitrate, phosphate, and sulfate may also be determined using these test methods. However, analysis of these ions is not the object of these test methods.
1.2 It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.
1.3 These test methods are technically equivalent with Part B of U.S. EPA Method 300.1,2 titled "The Determination of Inorganic Anions in Drinking Water by Ion Chromatography."
1.4 The values stated in either SI or inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Document History