UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

ASTM International - ASTM C191-18

Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle

inactive
Buy Now
Organization: ASTM International
Publication Date: 15 June 2018
Status: inactive
Page Count: 8
ICS Code (Cement. Gypsum. Lime. Mortar): 91.100.10
significance And Use:

5.1 This test method provides a means of determining compliance with a specification limit for Vicat time of setting. Refer to the appropriate specification for the cement to determine if this... View More

scope:

1.1 These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated standard Vicat apparatus, while Method B permits the use of an automatic Vicat machine that has, in accordance with the qualification requirements of this method, demonstrated acceptable performance.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Warning:  Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2

1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

Note 1: For the method for determining the time of setting by Gillmore needles, see Test Method C266.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

October 1, 2021
Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Test Method A is the Reference Test Method using the manually...
August 1, 2019
Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
October 1, 2018
Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
ASTM C191-18
June 15, 2018
Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
December 1, 2013
Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
June 1, 2008
Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
July 15, 2007
Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
November 1, 2004
Standard Test Method for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
July 1, 2004
Standard Test Method for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
January 1, 2004
Standard Test Method for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
July 10, 2003
Standard Test Method for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
November 10, 2001
Standard Test Method for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
November 10, 2001
Standard Test Method for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
November 10, 2001
Standard Test Method for Time of Setting of Hydraulic Cement by Vicat Needle
1.1 These methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated...
Advertisement