CSA - CGA P.6-1993

Testing Method for Measuring Thermal and Operating Efficiencies of Gas-Fired Pool Heaters

inactive
Organization: CSA
Publication Date: 1 March 1993
Status: inactive
Page Count: 23
scope:

PURPOSE

The purpose of this document is to provide a method of measuring the thermal efficiency of Convection and Other than Convection (forced circulation) swimming pool heaters.

SCOPE 

This document applies to Gas-fired Swimming Pool Heaters at all inputs utilizing natural gas or propane fuel

DEFINITIONS

Annual Energy consumption means the product of appliance nameplate input and burner annual operating hours

Draft Hood A device built into the appliance, or made part of the vent connector from an appliance, which is designed to:

         1 Provide for the ready escape of the flue gases in the event of no draft, back-draft or stoppage beyond the draft hood;

         2 Prevent a back draft from entering the appliance

         3 Neutralize the effect of stack action of the chimney or gas vent upon the operation of the appliance

Document History

January 1, 2009
Test method for measuring thermal efficiency of gas-fired pool heaters
This Standard specifies the test method for measuring the thermal efficiency of gas-fired swimming pool heaters. This Standard applies to newly produced pool heaters (constructed entirely of new...
January 1, 2009
Test method for measuring thermal efficiency of gas-fired pool heaters
This Standard specifies the test method for measuring the thermal efficiency of gas-fired swimming pool heaters. This Standard applies to newly produced pool heaters (constructed entirely of new...
March 1, 1993
Testing Method for Measuring Thermal and Operating Efficiencies of Gas-Fired Pool Heaters
This document applies to Gas-fired Swimming Pool Heaters at all inputs utilizing natural gas or propane fuel. PURPOSE The purpose of this document is to provide a method of measuring the thermal...
CGA P.6-1993
March 1, 1993
Testing Method for Measuring Thermal and Operating Efficiencies of Gas-Fired Pool Heaters
PURPOSE The purpose of this document is to provide a method of measuring the thermal efficiency of Convection and Other than Convection (forced circulation) swimming pool heaters. SCOPE  This...
March 1, 1993
Testing Method for Measuring Thermal and Operating Efficiencies of Gas-Fired Pool Heaters
This document applies to Gas-fired Swimming Pool Heaters at all inputs utilizing natural gas or propane fuel. PURPOSE The purpose of this document is to provide a method of measuring the thermal...