CGSB - CAN/CGSB-3.0 NO. 14.3-99
Methods of Testing Petroleum and Associated Products Standard Test Method for the Identification of Hydrocarbon Components in Automotive Gasoline Using Gas Chromatography
| Organization: | CGSB |
| Publication Date: | 1 June 1999 |
| Status: | inactive |
| Page Count: | 57 |
| ICS Code (Physicochemical methods of analysis): | 71.040.50 |
scope:
This test method is a standard procedure for the determination of paraffins, olefins, naphthenes, aromatics and unknowns (P.O.N.A.U.) in automotive gasolines using gas chromatography.
The final boiling pint of samples should not exceed that of nC15.
Individual hydrocarbon components or groups of coeluting components greater than or equal to 0.01% by mass are determined.
The separation of individual hydrocarbons by the procedure described in this test method is not absolute and will result in some peaks that represent coeluting compounds (Table 1).
A limitation of the method is that toluene and
2,3,3-trimethylpenta
The data obtained from analyzing three hundred and sixty-nine
Canadian automotive gasolines were used to develop this test
method. These data, excluding toluene and 2,3,3-trimethylpenta
From the gasolines analyzed, forty compounds with concentrations greater than 1% by mass have been found. These possible forty compounds constitute an average of 79% by mass of automotive gasoline. From these forty compounds which may be found in gasoline, this method identifies coeluting peaks for toluene, 2-methylhexane, methylcyclopentane and n-hexane (Table 1). The forty compounds are identified in Table 5 by an asterisk beside its identification number.
The number of coeluting peaks depends on the total number of individual compounds and the number of olefinic compounds present. The possibility of coeluting compounds increases with the increase of compounds detected after n-octane.
Oxygenated compounds may be determined by this test method. To analyze for oxygenated compounds, insert oxygenated compounds of interest (Table 2) in the hydrocarbon data table (Table 5). Due to the possibility of coeluting peaks in other areas, the user is cautioned in the interpretation of the data.
The testing and evaluation of a product against this method may require the use of materials and/or equipment that could be hazardous. This document does not purport to address all the safety aspects associated with its use. Anyone using this method has the responsibility to consult the appropriate authorities and to establish appropriate health and safety practices in conjunction with any applicable regulatory requirements prior to its use.
Document History