The strainers covered by this specification are intended for general
service to protect regulating valves, orifices, pumps, and other piping
equipment from damage or faulty operation which would... View More
The strainers covered by this specification are intended for general
service to protect regulating valves, orifices, pumps, and other piping
equipment from damage or faulty operation which would result from entrained
sediment particles.
The following ranges of perforation sizes and wire mesh numbers are
acceptable.
a. Perforation diameters, inches (approximate):
0.020 to 0.023
0.027 to 0.033
0.040 to 0.050
0.057 to 0.063
0.090 to 0.105
0.120 to 0.130
b. Mesh numbers - 20, 40, 60, 80, and 100.
The ratio of the net effective strainer area to the area of the pipe in an
indirect index of the resistance to flow through the strainer. The ratio cited
in 3.9.6 is a minimum value for the range of sizes covered by this
specification. Many designs of strainers provide for higher area-ratios. The
area-ratio is dependent upon the size of opening and the total surface area of
the element, and varies with the size of the strainer. If a higher ratio is
required, manufacturer's literature should be consulted to ascertain
availability of the required area-ratio,.