ASTM International - ASTM D4990-97a(2020)

Standard Specification for Coal-Tar Glass Felt Used in Roofing and Waterproofing

active
Buy Now
Organization: ASTM International
Publication Date: 1 May 2020
Status: active
Page Count: 2
ICS Code (Binders. Sealing materials): 91.100.50
scope:

1.1 This specification covers glass felt impregnated with coal-tar intended to be used with coal-tar pitch conforming to the appropriate requirements of Specification D450/D450M in construction of built-up roofs and in the construction of waterproofing systems.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 The following safety hazards caveat pertains only to the Test Methods portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

abstract:

This specification covers glass felt impregnated with coal tar intended to be used with coal tar pitch in the construction of built-up roofs and waterproofing systems. The felt shall be a thin,... View More

Document History

ASTM D4990-97a(2020)
May 1, 2020
Standard Specification for Coal-Tar Glass Felt Used in Roofing and Waterproofing
1.1 This specification covers glass felt impregnated with coal-tar intended to be used with coal-tar pitch conforming to the appropriate requirements of Specification D450/D450M in construction of...
May 15, 2013
Standard Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing
1.1 This specification covers glass felt impregnated with coal tar intended to be used with coal tar pitch conforming to the appropriate requirements of Specification D450 in construction of built-up...
March 1, 2005
Standard Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing
1.1 This specification covers glass felt impregnated with coal tar intended to be used with coal tar pitch conforming to the appropriate requirements of Specification D 450 in construction of...
July 10, 1997
Standard Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing
1.1 This specification covers glass felt impregnated with coal tar to be used with coal tar pitch conforming to the appropriate requirements of Specification D 450 in construction of built-up roofs...
Advertisement