TIA-455-199
FTOP-199 In-Line Polarization Crosstalk Measurement Method for Polarization-Maintaining Optical Fibers, Components, and Systems
| Organization: | TIA |
| Publication Date: | 1 December 2002 |
| Status: | inactive |
| Page Count: | 30 |
scope:
This Standard is applicable to single sections of PM fiber, to
cascaded PM fibers, and to PM fibers interconnected with optical
devices. It is also applicable to polarization-maintai
Hereafter the test device is referred to as the "sample". The sample must include a section of PM fiber along which the polarization crosstalk is to be measured.
This Standard complements FOTP-193, which describes the measurement of polarization crosstalk at a plane beyond the output interface of the sample.
The polarization crosstalk of PM itself, without connectors, tends to be proportional to fiber length. In such cases the proportionality constant, commonly referred to as the "h-parameter," is another measure of PM fiber performance. A test method for h-parameter is the subject of FOTP-192.
This method is restricted to wavelengths greater than or equal to that at which the fiber is effectively single-mode. The cutoff wavelength of an uncabled fiber may be determined by FOTP-80.