scope:
This specification covers a series of miniature, moisture proof connectors suitable for operation with shielded and unshielded cable up to 750 volts rms under severe environmental conditions.
Connectors covered by this specification shall be of the following series, classes, and types, as specified (see 3.1).
Series I - Plugs and receptacles, cable termination. Series II - Plugs and receptacles, permanent crimp, (using a standard MIL-C-22520 tool). Series III - Adapters, all types. Series IV - Plugs and receptacles, solder termination. Class G - General purpose. Class H - Hermetic, sealed cable termination. Class Y - Hermetic, adapters. Type 1 - Shield termination, continuous circuit, grounded. Type 2 - Shield termination, continuous circuit, isolated ground. Type 3 - Shield termination, interrupted ground. Type 4 - No shield termination. Type 5 - Class Y, grounded outer circuit. Type 6 - Class Y, ungrounded outer circuit.
The military part number shall consist of the letter "M" followed by the basic specification sheet number and a sequentially assigned dash number which is used to designate the polarity and a letter to designate the cable size as shown in the following example:
The mating interface of connectors covered by this specification shall be polarized as specified on figure 1 (see 3.1). Where connector configuration includes minor variables such as mounting features, solder terminations, etc. The first digit in the polarity dash number may be changed to show the variation. Dash number for polarities shall be as specified in table I. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to, Air Force Aquisition Logistics Division, (AFALD/PTES), Wright-Patterson AFB, OH 45433 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. TABLE I. Polarities.
Dash Polarity Uses
number
--------------------
Connectors covered by this specification shall be capable of terminating cables as designated per Appendix 1 when applicable (see 3.1).
intended Use:
The miniature coaxial connectors covered by this
specification are intended primarily for use in capacitance-type
fuel-quantity-measur