ASSE 1044

Performance Requirements for Trap Seal Primer Devices - Drainage Types and Electronic Design Types

inactive
Buy Now
Organization: ASSE
Publication Date: 23 February 2001
Status: inactive
Page Count: 17
scope:

Description

This standard covers devices designed primarily to supply water to floor drain traps which have infrequent use & in which water evaporation would allow sewer gas to enter the premises. These devices are designed to supply water to a drain trap to provide & maintain its water seal using a supply from a fixture drainline, ballcock, or flushometer valve tailpiece or an electronic primer device. The rate of water flow to the trap shall be permitted to be fixed or adjustable. The devices are of 4 types:

(a)Those installed on waste line tail pieces from fixtures, such as lavatories, sinks & similar fixtures where grease is not normally generated;

(b) Those used in conjunction with ballcock assemblies;

(c) Those which receive flow from flushometer valves; &

(d) Electronics devices which discharge water automatically & are upstream of the air gap or vacuum breaker.

Document History

February 1, 2023
Performance Requirements for Trap Seal Primer – Drainage Types and Electric Design Types
Description This standard covers trap primers used in conjunction with fill valves and flushometer valves, electrical trap primers and trap primer adapters, and specifies requirements for materials,...
March 1, 2015
Performance Requirements for Trap Seal Primer – Drainage Types and Electric Design Types
Description The trap seal primers are of four (4) types: a) Those that are installed on waste line tail pieces from fixtures, such as lavatories, sinks and similar fixtures where grease is not...
March 1, 2015
Performance Requirements for Trap Seal Primer - Drainage Types and Electric Design Types
Description The trap seal primers are of four (4) types: a) Those that are installed on waste line tail pieces from fixtures, such as lavatories, sinks and similar fixtures where grease is not...
ASSE 1044
February 23, 2001
Performance Requirements for Trap Seal Primer Devices - Drainage Types and Electronic Design Types
Description This standard covers devices designed primarily to supply water to floor drain traps which have infrequent use & in which water evaporation would allow sewer gas to enter the premises....
January 1, 1986
Performance Requirements for Trap Seal Primer Valves Drainage Type
A description is not available for this item.

References