DSF/prEN ISO 7198

Cardiovascular implants and extracorporeal systems - Vascular Prostheses - Tubular vascular grafts and vascular patches (ISO/DIS 7198:2014)

pending
Organization: DS
Status: pending
Page Count: 60
ICS Code (Implants for surgery, prosthetics and orthotics): 11.040.40
scope:

1.1 This International Standard specifies requirements for the evaluation of vascular prostheses and requirements with respect to nomenclature, design attributes and information supplied by the manufacturer, based upon current medical knowledge. Guidance for the development of in vitro test methods is included in an informative annex to this standard. This standard should be considered as a supplement to ISO 14630, which specifies general requirements for the performance of non-active surgical implants.With regard to safety, it gives requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and information supplied by the manufacturer. This standard is supplemental to ISO 14630, which specifies general requirements for the performance of non-active surgical implants. NOTE - Due to the variations in the design of implants covered by this International Standard and in some cases due to the relatively recent development of some of these implants (e.g. bioabsorbable vascular prostheses, cell based tissue engineered vascular prostheses), acceptable standardized in vitro tests and clinical results are not always available. As further scientific and clinical data become available, appropriate revision of this document will be necessary. 1.2 This International Standard includes is applicable to sterile tubular vascular prostheses implanted by direct visualization surgical techniques as opposed to fluoroscopic or other non-direct imaging (e.g., computerized tomography or magnetic resonance imaging), intended to replace, bypass, or form shunts between segments of the vascular system in humans and vascular patches intended for repair and reconstruction of the vascular system. 1.3 Vascular prostheses that are made of synthetic textile materials, and synthetic nontextile materials are included in thewithin the scope of this standard. 1.4 While vascular prostheses that are made wholly or partly of mate ...

Document History

March 7, 2017
Cardiovascular implants and extracorporeal systems – Vascular prostheses – Tubular vascular grafts and vascular patches (ISO 7198:2016)
ISO 7198:2016 specifies requirements for the evaluation of vascular prostheses and requirements with respect to nomenclature, design attributes and information supplied by the manufacturer, based...
Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO/FDIS 7198:2016)
1.1 This International Standard specifies requirements for the evaluation of vascular prostheses and requirements with respect to nomenclature, design attributes and information supplied by the...
DSF/prEN ISO 7198
Cardiovascular implants and extracorporeal systems - Vascular Prostheses - Tubular vascular grafts and vascular patches (ISO/DIS 7198:2014)
1.1 This International Standard specifies requirements for the evaluation of vascular prostheses and requirements with respect to nomenclature, design attributes and information supplied by the...