NR/L3/ELP/29987/MOD07 ISSUE 4

Working On or About 25 kV A.C. Electrified Lines: Isolation and Earthing of Overhead Line Equipment

inactive
Organization: NR
Publication Date: 6 September 2015
Status: inactive
Page Count: 52
scope:

This module states the requirements for the isolation, testing and earthing of overhead line equipment and the issue of overhead line permits on 25 kV a.c. electrified lines.

It is applicable to Network Rail personnel and to Network Rail's contractors. It is also applicable in relevant part to Train Operating Companies having locally controlled 25 kV a.c. overhead lines which abut those controlled by Network Rail.

To provide a consistent approach to working on or about 25 kV a.c. electrified lines, Train Operating Companies may, as best practice, apply this standard in full on infrastructure they control.

Purpose

This module will promote safe operation of the 25 kV a.c. electrification system and produce consistent implementation of secure isolation procedures. Further requirements for working on or about the electrified lines and for communication are contained in the Rule Book Modules AC and G1 (GE/RT8000/AC and GE/RT8000/G1).

Document History

Working on or About 25 kV A.C. Electrified Lines: Isolation and Earthing of Overhead Line Equipment
This module states the requirements for the isolation, testing and earthing of overhead line equipment and the issue of overhead line permits on 25 kV a.c.electrified lines. It is applicable to...
September 3, 2022
Working on or About 25 kV A.C. Electrified Lines: Isolation and Earthing of Overhead Line Equipment
This module states the requirements for the isolation, testing and earthing of overhead line equipment and the issue of overhead line permits on 25 kV a.c. electrified lines. It is applicable to...
Working on or About 25 kV A.C. Electrified Lines: Isolation and Earthing of Overhead Line Equipment
This module states the requirements for the isolation, testing and earthing of overhead line equipment and the issue of overhead line permits on 25 kV a.c. electrified lines.  It is applicable to...
September 4, 2021
Working on or About 25 kV A.C. Electrified Lines: Isolation and Earthing of Overhead Line Equipment
This module states the requirements for the isolation, testing and earthing of overhead line equipment and the issue of overhead line permits on 25 kV a.c. electrified lines. It is applicable to...
December 1, 2018
Working On or About 25 kV A.C. Electrified Lines: Isolation and Earthing of Overhead Line Equipment
This module states the requirements for the isolation, testing and earthing of overhead line equipment and the issue of overhead line permits on 25 kV a.c. electrified lines. It is applicable to...
NR/L3/ELP/29987/MOD07 ISSUE 4
September 6, 2015
Working On or About 25 kV A.C. Electrified Lines: Isolation and Earthing of Overhead Line Equipment
This module states the requirements for the isolation, testing and earthing of overhead line equipment and the issue of overhead line permits on 25 kV a.c. electrified lines. It is applicable to...

References