DS/EN 61726

Cable assemblies, cables, connectors and passive microwave components – Screening attenuation measurement by the reverberation chamber method

active, Most Current
Buy Now
Organization: DS
Publication Date: 27 November 2015
Status: active
Page Count: 22
ICS Code (RF connectors): 33.120.30
ICS Code (Coaxial cables. Waveguides): 33.120.10
scope:

IEC 61726:2015(E) describes the measurement of screening attenuation by the reverberation chamber test method, sometimes named mode stirred chamber, suitable for virtually any type of microwave component and having no theoretical upper frequency limit. It is only limited toward low frequencies due to the size of the test equipment, which is frequency-dependent and is only one of several methods of measuring screening attenuation. For the purpose of this standard, examples of microwave components are waveguides, phase shifters, diplexers/multiplexers, power dividers/combiners etc. This third edition cancels and replaces the second edition, published in 1999. This edition constitutes a technical revision. It takes into account the latest developments in the design of reverberation chambers as described in IEC 61000-4-21, which is also referencing this standard as a possible test method. Furthermore, an alternative measurement procedure is added which is able to reduce the measurement time needed.

Document History

DS/EN 61726
November 27, 2015
Cable assemblies, cables, connectors and passive microwave components – Screening attenuation measurement by the reverberation chamber method
IEC 61726:2015(E) describes the measurement of screening attenuation by the reverberation chamber test method, sometimes named mode stirred chamber, suitable for virtually any type of microwave...
August 18, 2000
Cable assemblies, cables, connectors and passive microwave components – Screening attenuation measurement by the reverberation chamber method
This technical report describes the reverberation chamber method, sometimes named mode stirred chamber, suitable for virtually any type of microwave component and having no theoretical frequency...
Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method
The requirements of modern electronic equipment have indicated a demand for a method for testing screening attenuation of microwave components over their whole frequency range. Convenient test...
Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method
A description is not available for this item.

References