This specification covers a high fire point natural vegetable oil ester insulating fluid for use as a dielectric and cooling medium in new and existing power and distribution electrical apparatus such as transformers and attendant equipment. The physical property requirement including color, fire...
1.1 This practice covers the determination of the coefficient of thermal expansion of electrical insulating liquids of petroleum origin, and askarels, containing PCBs (polychlorinated biphenyls), when used as an insulating or cooling medium, or both, in cables, transformers, oil circuit...
1.1 This test method2 covers a two-tiered analytical approach to PCB screening and quantitation of liquid and solid wastes, such as oils, sludges, aqueous solutions, and other waste matrices. 1.2 Tier I is designed to screen samples rapidly for the presence of PCBs. 1.3 Tier II is...
1.1 This practice addresses sampling of organic compounds (that is, PCBs, dioxins, many pesticides, and similar compounds) from smooth nonporous surfaces using a solvent-wetted wipe sampling method. Samples are collected in a manner that permits the solvent extraction of the organic...
This specification covers two types of new mineral insulating oils of petroleum origin for use as an insulating and cooling medium in new and existing power and distribution electrical apparatuses, such as transformers, regulators, reactors, circuit breakers, switchgear, and attendant equipment. It...
1.1 This ASTM guide identifies publicly available tools that screen communities threatened by climate change and multi-source environmental pollution. 1.2 The guide provides resources including a process for selecting the appropriate tool(s) to help make decisions that meet regulatory requirements...
5.1 Pesticides and PCBs are Environmental Protection Agency (EPA)-regulated contaminants in treated drinking water, wastewater, and ground water. Liquid-liquid and solid-phase extraction (SPE) are generally applicable procedures for extracting these target analytes before GC/MS/MS analysis....
5.1 The extensive and widespread use of organochlorine pesticides and PCBs has resulted in their presence in all parts of the environment. These compounds are persistent and may have adverse effects on the environment. Thus, there is a need to identify and quantitate these compounds in water...
This specification covers two types of new mineral insulating oils of petroleum origin for use as an insulating and cooling medium in new and existing power and distribution electrical apparatuses, such as transformers, regulators, reactors, circuit breakers, switchgear, and attendant equipment. It...
5.1 Pesticides and PCBs are Environmental Protection Agency (EPA)-regulated contaminants in treated drinking water, wastewater, and ground water. Liquid-liquid and solid-phase extraction (SPE) are generally applicable procedures for extracting these target analytes before GC/MS/MS analysis....
1.1 This practice covers the sampling of air for a variety of common pesticides and polychlorinated biphenyls (PCBs) and provides guidance on the selection of appropriate analytical measurement methods. Other compounds such as polychlorinated dibenzodioxins/furan
1.1 These practices cover sampling of new electrical insulating liquids including oils, askarels, silicones, synthetic liquids, and natural ester insulating liquids as well as those insulating liquids in service or subsequent to service in cables, transformers, circuit breakers, and other...
5.1 This test method is meant to allow for a rapid (24 h) index of a geomedia's sorption affinity for given solutes in environmental waters or leachates. A large number of samples may be run in parallel using this test method to determine a comparative ranking of those samples, based upon the...
This specification describes a high fire-point mineral oil based electrical insulating fluid, for use as a dielectric and cooling medium in new and existing power and distribution electrical apparatuses, such as transformers and switchgear. The material discussed here is miscible with other...
Included in the scope of this SIN is all E&P oil filled equipment, including that maintained by others, with an oil volume equal to or greater than 5dm3 (5 litres) and either: • a year of manufacture up to and including 1986, or • a year of installation up to and including 1987, or • a year of...
1.1 This is a guide for determining the appropriate method or combination of methods for the estimation of natural attenuation or depletion rates at sites with non-aqueous phase liquid (NAPL) contamination in the subsurface. This guide builds on a number of existing guidance documents worldwide and...
1.1 This test method2 covers a two-tiered analytical approach to PCB screening and quantitation of liquid and solid wastes, such as oils, sludges, aqueous solutions, and other waste matrices. 1.2 Tier I is designed to screen samples rapidly for the presence of PCBs. 1.3 Tier II is...
1.1 This guide describes methods of testing and specifications for electrical insulating liquids intended for use in electrical cables, transformers, liquid-filled circuit breakers, and other electrical apparatus where the liquids are used as insulating, or heat transfer media, or both. 1.2 The...
1.1 This standard covers procedures for obtaining laboratory data concerning the toxicity of test material (for example, sediment or hydric soil (that is, a soil that is saturated, flooded, or ponded long enough during the growing season to develop anaerobic (oxygen-lacking) conditions that favor...