This standard test method covers the determination of silicon in engine coolant concentrates by atomic absorption spectroscopy. Apparatus and reagents used for this test method include atomic absorption spectrometer, hollow-cathode lamp, reagent grade chemicals, standard...
1.1 This practice covers the optimization of graphite furnace atomic absorption spectrometers and the checking of spectrometer performance criteria. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety...
4.1 This practice is for optimizing the parameters used in the determination of trace elements in metals and alloys by the graphite furnace atomic absorption spectrometric method. It also describes the practice evaluating spectrometer performance. The work is expected to be performed...
1.1 This practice covers general considerations for the quantitative determination of elements in water and waste water by flame atomic absorption spectrophotometry. Flame atomic absorption spectrophotometry is simple, rapid, and applicable to a large number of elements...
5.1 Barium ranks about sixth in order of abundance in nature; however, it is normally found in only trace quantities in drinking water. Consumption, inhalation, or absorption of 500?mg to 600?mg is considered fatal to human beings. Lower levels may result in disorders of the heart, blood...
1.1 This test method covers the determination of copper in jet fuels in the range of 5?μg/kg to 100?μg/kg using graphite furnace atomic absorption spectrometry. Copper contents above 100?μg/kg may be determined by sample dilution with kerosine to bring the copper level into the...
This test method covers atomic absorption tests applicable to powdered laundry detergents containing clay and zeolite. The test sample is fused with lithium metaborate, dissolved in acid, its silicon and aluminum content measured by atomic absorption, and the...
1.1 These test methods cover the determination of metals in rubber compounding materials by flame atomic absorption. 1.2 The test methods include the following materials: Sections Zinc oxide 11 - 20 1.3 The values stated in SI units are to be regarded as standard. No other units of...
1.1 This test method covers analysis of nickel alloys by flame atomic absorption spectrometry (FAAS) for the following elements: Element Compostiton Range, % Aluminum 0.2 to 4.0 Chromium 0.01 to 4.0 Cobalt 0.01 to 4.0 Copper 0.01 to 4.0 Iron 0.1 to 4.0 Manganese 0.1 to 4.0 Silicon 0.2...
1.1 This test method covers the atomic absorption procedure, using nitrous oxide-acetylene flame, air-acetylene flame or ICP (inductively coupled plasma) to analyze the chrome content of crust (and leather) on a moisture-free basis. 1.2 The values stated in SI units are to be regarded...
5.1 Accurate elemental analysis of petroleum products and lubricants is necessary for the determination of chemical properties, which are used to establish compliance with commercial and regulatory specifications. 5.2 Atomic Absorption Spectrometry (AAS) is one of the most widely used...
5.1 The procedure described is for chromium in Wet Blue using Atomic Absorption or ICP. This method may be used to determine the chromium content in Wet Blue as an alternate to Test Method D6656. 5.2 The chromium content of Wet Blue is related to the degree of tannage obtained, and...
5.1 This test method is significant for applications where iron leaching may affect product quality, such as in food, chemical purification, or decolorization processes. 5.2 Users should validate equipment performance, ensuring no interferences from other sample matrix components. 5.3 Ensure...
1.1 This test method covers the determination of the acid soluble iron content of granular and powdered activated carbons, using an atomic absorption spectroscopy method by direct aspiration. Hydrochloric acid is used to extract the iron. This test method is not directly usable to...
4.1 These test methods are suitable for process control, for product acceptance, and for research and development.
1.1 This test method covers procedures for using graphite furnace atomic absorption spectroscopy (GFAAS) to quantitatively determine lead and cadmium extracted by acetic acid at room temperature from the food-contact surface of foodware. The method is applicable to food-contact...
1.1 This test method covers the determination of lead (Pb) in airborne particulate, dust by wipe and micro-vacuuming, paint, and soil collected in and around buildings and related structures using graphite furnace atomic absorption spectrometry (GFAAS). 1.2 This test method contains...
1.1 This test method covers the collection, dissolution, and determination of trace metals in workplace atmospheres, by flame atomic absorption spectrophotometry (FAAS). 1.2 The estimated method detection limits and optimum working concentration ranges for 21 metals are given in Table...
1.1 This test method covers the determination of lead (Pb) in airborne particulate, dust by wipe and micro-vacuuming, paint, and soil collected in and around buildings and related structures by flame atomic absorption spectrophotometry (FAAS) and is derived from Test Methods D4185 and...
1.1 These test methods cover procedures for the chemical and atomic absorption analysis of uranium-ore concentrates to determine compliance with the requirements prescribed in Specification C967. 1.2 The analytical procedures appear in the following order: Sections Uranium by Ferrous...