1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in tin bronze and related alloy castings. The reference radiograph films are an adjunct to this document and must be purchased separately from ASTM International if needed...
4.1 Graded reference radiographs are intended to provide a guide enabling recognition of specific casting discontinuity types and relative severity levels that may be encountered during typical fabrication processes. Reference radiographs containing ungraded discontinuities are provided as a...
1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in steel castings that have section thicknesses up to 2 in. (50.8 mm) (see Note 2). The reference radiograph films are an adjunct to this standard and must be purchased...
1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in steel castings that have section thicknesses of 41/2 in. to 12?in. (114?mm to 305 mm). The reference radiograph films are an adjunct to this document and must be...
1.1 These digital reference images illustrate various categories, types, and severity levels of discontinuities occurring in tin bronze and related alloy castings. The digital reference images are an adjunct to this document and must be purchased separately from ASTM International if needed...
1.1 This practice covers the procedures for testing the performance of ultraviolet A (UV-A), light emitting diode (LED) lamps used in fluorescent penetrant and fluorescent magnetic particle testing (see Guides E709 and E2297, and Practices E165/E165M, E1208, E1209, E1210, E1219, E1417/E1417M, and...
1.1 This practice covers the procedures for testing the performance of ultraviolet A (UV-A), light emitting diode (LED) lamps used in fluorescent penetrant and fluorescent magnetic particle testing (see Guides E709 and E2297, and Practices E165/E165M, E1208, E1209, E1210, E1219, E1417/E1417M, and...
5.1 This test method, used for specification purposes, differentiates between lubricating greases having low, medium, and high level of extreme-pressure properties. The results do not necessarily correlate with results from service. 5.2 It is noted that lubricating greases that have...
5.1 This section elaborates how the GMPC may be used in the context of the two main approaches to managing the execution of transportation mentioned in 4.8. These elaborations do not go into every possible detail of these approaches. The purpose of the elaborations is to provide an outline of the...
1.1 The global supply chain involves 5 distinct phases; the first and last are not included in the Goods Movement Process (as defined in Terminology F3682; see also Fig. 1). 1.1.1 The Goods Movement Process' three phases are the Planning Phase, the Execution Phase, and the Reconciliation Phase. At...
1.1 This guide provides specific requirements to statistically evaluate measurand alarm thresholds, which are called alarm limits, as they are applied to data collected from in-service oil analysis. These alarm limits are typically used for condition monitoring to produce severity...
4.1 Management of asbestos-containing materials in buildings and facilities requires knowledge of the location, type, quantity, and condition of the material. The more complete and accurate the information available, the more appropriate and cost-effective are the control measures used to reduce...
4.1 This guide is an aid to the user by providing information that can be used to develop PFAS environmental field sampling plans. A PFAS sampling plan requires a heightened level of rigor to avoid cross contamination and achieve the level of data quality needed to achieve project...
1.1 This test method covers the laboratory determination of the rate at which organic biocide is released from an antifouling coating exposed in substitute ocean water. The test is run entirely in the laboratory under controlled conditions of pH, temperature, salinity, and hydrodynamics. Analytical...
4.1 This practice is intended to apply to all translation projects regardless of the translation service provider selected (see Section 7). This practice does not apply to spoken or signed interpreting services. For interpreting, please consult Practice F2089, Practice for Language...
5.1 Community knowledge and experience related to emergency response to threats with a biological agent or toxin at the federal, state, tribal, and local levels has been translated into a guide to assist responder agencies' progress toward the goal of building operational guidelines for the...
1.1 This test method describes the continuous measurement of the hemispherical heat flux to one or both surfaces of an uncooled sensor called a "Directional Flame Thermometer" (DFT). 1.2 DFTs consist of two heavily oxidized, Inconel 600 plates with mineral insulated, metal-sheathed (MIMS)...
1.1 This specification2 covers carbon and alloy steel pipe, electric-fusion-weld
Narrow Your Results