1.1 This practice covers minimum requirements for the design and manufacture of Electric Propulsion Units (EPU) for light sport aircraft, VFR use. The EPU shall as a minimum consist of the electric engine, associated controllers, disconnects and wiring, an Energy Storage Device (ESD) such as a...
4.1 For certain applications when insulating liquid is stressed at high voltage gradients, it is desirable to be able to determine the rate of gas evolution or gas absorption under specified test conditions. At present time correlation of such test results with equipment performance is limited. 4.2...
1.1 This practice covers the determination of the coefficient of thermal expansion of electrical insulating liquids of petroleum origin, and askarels, containing PCBs (polychlorinated biphenyls), when used as an insulating or cooling medium, or both, in cables, transformers, oil circuit breakers,...
This specification covers the electrical, visual, and physical properties of natural blocks and films made from mica that are suitable for use in fixed mica-dielectric capacitors. The materials under this specification are of three forms and four classes. Samples should be taken and tested...
1.1 This test method determines the minimum ignition energy of a dust cloud in air by a high voltage spark. 1.2 The minimum ignition energy (MIE) of a dust-cloud is primarily used to assess the likelihood of ignition during processing and handling. The likelihood of ignition is used to evaluate the...
5.1 Concepts: 5.1.1 All TDEM/TEM instruments are based on the concept that a time-varying magnetic field generated by a change in the current flowing in a large loop on the ground will cause current to flow in the earth below it (Fig. 3). In the typical TDEM/TEM system, these earth-induced currents...
This specification covers the requirements for porous oxide coatings deposited by electrolysis on aluminum and aluminum alloy parts. These coatings should have good appearance, abrasion resistance, electrical properties, and protection against corrosion and does not include nonporous barrier layer...
1.1 This test method covers the detection and measurement of partial discharge (corona) pulses at the terminals of an insulation system under an applied test voltage, including the determination of partial discharge (corona) inception and extinction voltages as the test voltage is raised and...
4.1 Flash X-ray facilities provide intense bremsstrahlung radiation environments, usually in a single sub-microsecond pulse, which often fluctuates in amplitude, shape, and spectrum from shot to shot. Therefore, appropriate dosimetry must be fielded on every exposure to characterize the...
1.1 This test method covers the determination of the dissipation factor and the relative permittivity of natural block mica having thicknesses between 0.007 and 0.030 in. (0.18 and 0.77?mm) and mica films or capacitor splits between 0.0008 and 0.004 in. (0.02 and 0.10 mm) in thickness. 1.2...
4.1 Dissipation Factor (or Power Factor)-This is a measure of the dielectric losses in an electrical insulating liquid when used in an alternating electric field and of the energy dissipated as heat. A low dissipation factor or power factor indicates low ac dielectric losses. Dissipation factor or...
1.1 This Standard covers the sorting and grading process of battery packs, modules and cells and electrochemical capacitors that were originally configured and used for other purposes, such as electric vehicle propulsion, and that are intended for a repurposed use application, such as for...
Batteries for Use In Light Electric Vehicle (LEV) Applications ANSI/CAN/UL/ULC 2271 1.1 These requirements cover electrical energy storage assemblies (EESAs) such as battery packs and combination battery pack-electrochemical
Batteries for Use In Light Electric Vehicle (LEV) Applications ANSI/CAN/UL/ULC 2271 1.1 These requirements cover electrical energy storage assemblies (EESAs) such as battery packs and combination battery pack-electrochemical
5.1 This test method applies to all papers made from unmodified cellulose, as used in transformer, cable, or capacitor manufacture. It applies to new or aged papers. For information, Appendix X1 shows an example of statistical distribution of values for new papers intended for the insulation...
5.1 The availability of a standard procedure, standard material, and standard plots should allow the investigator to check his laboratory technique. This practice should lead to electrochemical impedance curves in the literature which can be compared easily and with confidence. 5.2 Samples of a...
1.1 These test methods cover procedures for sampling and testing untreated paper to be used as an electrical insulator or as a constituent of a composite material used for electrical insulating purposes. 1.1.1 Untreated papers are thin, fibrous sheets normally laid down from a water suspension of...
1.1 This practice covers minimum requirements for the design and manufacture of Electric Propulsion Units (EPU) for light sport aircraft, VFR use. The EPU shall as a minimum consist of the electric motor, associated controllers, disconnects and wiring, an Energy Storage Device (ESD) such as a...
This SAE Recommended Practice establishes uniform chassis dynamometer test procedures for hybrid-electric vehicles (HEVs) and plug-in hybrid-electric vehicles (PHEVs) designed for public roads. This recommended practice provides instructions for measuring and calculating the exhaust emissions and...
5.1 Permittivity-Insulat
Narrow Your Results