This specification covers the minimum requirements for construction of fiber-reinforced thermoset plastic fans (both centrifugal and axial) and blowers, and provides for a common basis for determining safe operating speeds. The fan housing shall be of laminate construction...
This document deals with the likely degradation of air performance of fans tested in standardized airways in accordance with ISO 5801 when compared with the performance of fans tested under actual site conditions. It deals with the performance of a number of generic...
This document deals with the likely degradation of air performance of fans tested in standardized airways in accordance with ISO 5801 when compared with the performance of fans tested under actual site conditions. It deals with the performance of a number of generic...
This part of ECMA-275 specifies methods for measuring the airborne noise emitted by small air-moving devices (AMDs), such as those used for cooling electronic, electrical, and mechanical equipment where the sound power level of the AMD is of interest. Examples of these AMDs include propeller...
This standard applies to Central Station Air-handling Units, as defined in Section 3. This standard applies to Supply Fan ratings for Central Station Air-handling Units with Plenum Fans in a cabinet, Fan Arrays, Housed Centrifugal Fans, and Axial Fans....
This standard applies to Central Station Air-handling Units, as defined in Section 3. This standard applies to Supply Fan ratings for Central Station Air-handling Units with Plenum Fans in a cabinet, Fan Arrays, Housed Centrifugal Fans, and Axial Fans....
The mechanical test requirements for castings are given in the material specification in ASTM. Examples would be impact properties for grade LCC in A352, tensile strength requirements for grade 4N in A487, or ductility minimums for grade 70-40 in A27. The properties were developed for these...
This Practice describes manufacturing and performance requirements for single-stage, general purpose centrifugal process, induced draft and forced draft fans in noncritical service. Purpose This Practice provides requirements for manufacturing and testing centrifugal...
This specification covers the minimum requirements for construction of fiber-reinforced thermoset plastic fans (both centrifugal and axial) and blowers, and provides for a common basis for determining safe operating speeds. The fan housing shall be of laminate construction...
Thoroughly revised, this book provides the reader with an understanding of the principles and practices of testing and balancing (TAB) heating, ventilating, and air conditioning (HVAC) air and water systems. For the novice and the experienced testing and balancing technician, it is a...
This part of this American National Standard specifies methods for measuring the airborne noise emitted by small air‐moving devices (AMDs), such as those used for cooling electronic, electrical, and mechanical equipment where the sound power level of the AMD is of interest. Examples of these AMDs...
This part of ISO 10302 specifies methods for measuring the airborne noise emitted by small air-moving devices (AMDs), such as those used for cooling electronic, electrical, and mechanical equipment where the sound power level of the AMD is of interest. Examples of these AMDs include propeller...
This part of ISO 10302 specifies methods for measuring the airborne noise emitted by small air-moving devices (AMDs), such as those used for cooling electronic, electrical, and mechanical equipment where the sound power level of the AMD is of interest. Examples of these AMDs include propeller...
1.1 In a broad sense, this terminology covers terminology associated with liquid particles dispersed in gas. The principal emphasis, however, is on particles produced by the process of atomization. 1.2 All terms, followed by their definitions, are arranged alphabetically. In addition, the...
The HVAC Systems Commissioning Manual is intended to cover the full range of HVAC equipment and systems typically found in commercial and institutional buildings. The level of commissioning varies to suit the specific requirements of each project as determined by the owner. The manual describes in...